# 10 kVA 250/1000 V tests, equivalent circuit

Electrical Machines · Chapter 2: Transformer

- Asked in: 2073 Bhadra (old course), 8 marks
- Video: [EE213 - 09b - Determining equivalent circuit parameters for a transformer - numerical example](https://www.youtube.com/watch?v=b_6NbUb7U1o) — MAFarooqi
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_4/electrical_machines/tf-10kva-250-1000-parameters
- Whole chapter: https://www.bctengineer.com/md/semester_4/electrical_machines/chapter-2

## Question

The data obtained from the test of a 10 kVA, 250 V/1000 V single phase transformer are given below:
No-load test (on L.V side): 250 V, 0.8 A, 80 watt
Short circuit test (on H.V side): 80 V, 10 A, 120 watt
Calculate the equivalent circuit parameters referred to primary side and draw the equivalent circuit.

## Short answer

Open-circuit test yields shunt branch R0 = 781.25 Ω, X0 = 341 Ω. Short-circuit test gives equivalent series parameters referred to primary: Req = 0.075 Ω, Xeq = 0.4943 Ω (Zeq ≈ 0.5 Ω).

## Answer

**Given:** 10 kVA, 250 V/1000 V. Primary = LV (250 V), $K = 1000/250 = 4$, $K^2 = 16$. Rated HV current $= 10\,000/1000 = 10$ A, so the SC test is at full load.

#### Open-circuit test (on the LV side)

The no-load power is almost entirely core loss, so the shunt branch is found from it.

$$
\begin{aligned}
\cos\phi_0 &= \frac{P_0}{V_0I_0} = \frac{80}{250\times0.8} = 0.4 \\
I_w &= I_0\cos\phi_0 = 0.32\ \text{A},\qquad I_\mu = \sqrt{I_0^2 - I_w^2} = 0.7332\ \text{A} \\
R_0 &= \frac{V_0}{I_w} = 781.25\ \Omega,\qquad X_0 = \frac{V_0}{I_\mu} = 341\ \Omega\quad(\text{on the LV side})
\end{aligned}
$$

#### Short-circuit test (on the HV side)

At the reduced test voltage the core loss is negligible, so the wattmeter reading is the copper loss.

$$
\begin{aligned}
Z_{sc} &= \frac{V_{sc}}{I_{sc}} = \frac{80}{10} = 8\ \Omega \\
R_{sc} &= \frac{P_{sc}}{I_{sc}^2} = \frac{120}{10^2} = 1.2\ \Omega \\
X_{sc} &= \sqrt{Z_{sc}^2 - R_{sc}^2} = 7.909\ \Omega\quad(\text{on the HV side})
\end{aligned}
$$

#### Referring to the LV side

The turns ratio is $K = 1000/250 = 4$, so $K^2 = 16$. Impedances are multiplied by $K^2$ when moved from LV to HV, and divided by $K^2$ when moved from HV to LV.

$$
\begin{aligned}
R_{eq} &= 1.2 \div 16 = 0.075\ \Omega \\ X_{eq} &= 7.909 \div 16 = 0.4943\ \Omega
\end{aligned}
$$

#### Equivalent circuit referred to the LV side

```text
   Req=0.075 ohm   Xeq=0.494 ohm
 o--+-----/\/\/\-----UUUU------o
    |                          
   [R0=781.25] [X0=341]   Load
    |      (in parallel)
 o--+---------------------------o
```

$R_{eq} = 0.075\ \Omega$, $X_{eq} = 0.4943\ \Omega$ ($Z_{eq} = 0.5\ \Omega$), shunt branch $R_0 = 781.25\ \Omega$ in parallel with $X_0 = 341\ \Omega$.

**Answer (referred to primary):** $R_0 = 781.25\ \Omega$, $X_0 = 341.0\ \Omega$, $R_{01} = 0.075\ \Omega$, $X_{01} = 0.4943\ \Omega$ ($Z_{01} = 0.5\ \Omega$)

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. For the 10 kVA, 250/1000 V transformer, why is the SC test current of 10 A a full-load test?
   A. Because 10 kVA / 250 V = 10 A on the LV side
   B. Because rated HV current is 10000/1000 = 10 A
   C. Because 10 A is always used in SC tests
   D. Because the SC voltage is 80 V
   Answer: B. The SC test is on the HV side, whose rated current is S/V = 10000/1000 = 10 A, so the copper loss of 120 W is the full-load value. (Key point: Rated HV current check)

2. From the OC test (250 V, 0.8 A, 80 W) on the LV side, what are cos(phi0) and Iw?
   A. cos(phi0) = 0.4, Iw = 0.32 A
   B. cos(phi0) = 0.4, Iw = 0.7332 A
   C. cos(phi0) = 0.32, Iw = 0.8 A
   D. cos(phi0) = 0.9165, Iw = 0.7332 A
   Answer: A. cos(phi0) = 80/(250x0.8) = 0.4 and Iw = I0 cos(phi0) = 0.32 A, giving R0 = 250/0.32 = 781.2 Ω. (Key point: Shunt branch parameters)

3. The SC values Rsc = 1.2 Ω and Zsc = 8 Ω are on the HV side with K = 4. Referred to the primary (LV) side, Zeq is
   A. 128 Ω
   B. 2 Ω
   C. 8 Ω
   D. 0.5 Ω
   Answer: D. HV to LV means dividing by K^2 = 16: 8/16 = 0.5 Ω. Likewise R01 = 1.2/16 = 0.075 Ω. (Key point: Referring to the primary (LV))

4. How is the SC reactance obtained?
   A. Xsc = Vsc / Isc
   B. Xsc = Psc / Isc
   C. Xsc = sqrt(Zsc^2 - Rsc^2)
   D. Xsc = Zsc + Rsc
   Answer: C. Zsc is the vector sum of R and X, so X = sqrt(Z^2 - R^2) = sqrt(64 - 1.44) = 7.909 Ω. (Key point: Reactance from SC test)

## Related in Electrical Machines

- [Equivalent circuit of 10 kVA 250/1000 V transformer](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Aoc-sc-10kva-250-1000-primary) — Electrical Machines I, chapter 2, asked 2×
- [20 kVA 250/2500 V tests, equivalent circuit](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines%3Atf-20kva-250-2500-parameters) — Electrical Machines, chapter 2, asked 2×
- [25 kVA 250/2500 V tests, equivalent circuit](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines%3Atf-25kva-250-2500-parameters) — Electrical Machines, chapter 2, asked 2×
- [8 kVA 400/120 V tests, parameters on HV side](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines%3Atf-8kva-400-120-efficiency-hv) — Electrical Machines, chapter 2
- [Equivalent circuit of 20 kVA 250/2500 V transformer from tests](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Aoc-sc-20kva-250-2500) — Electrical Machines I, chapter 2, asked 3×
- [20 kVA 2200/220 V tests, equivalent circuit LV side](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines%3Atf-20kva-2200-220-lv-equivalent) — Electrical Machines, chapter 2

## Related in other subjects

- [20 kVA 250/2500 V test parameters](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machine%3Atransformer-20kva-250-2500-primary) — Electrical Machine, chapter 2, asked 2×
- [Equivalent circuit of 20 kVA 220/2200 V transformer](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Aoc-sc-20kva-220-2200-primary) — Electrical Machines I, chapter 2
- [8 kVA 400/120 V tests, half-load efficiency](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machine%3Atransformer-8kva-400-120-hv-side) — Electrical Machine, chapter 2
- [Transformer equivalent circuit referred to primary](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Aequivalent-circuit-referred-primary) — Electrical Machines I, chapter 2