title: "LRU replacement with hit and miss"
subject: "Computer Organization and Architecture"
chapter: 6
key: "semester_5/computer_organization_and_architecture:lru-replacement"
source: https://www.bctengineer.com/q/semester_5/computer_organization_and_architecture/lru-replacement
site: BCT Engineering
---

# LRU replacement with hit and miss

Computer Organization and Architecture · Chapter 6: Memory System

- Asked in: 2078 Bhadra, 8 marks
- Video: [L-3.13: LRU (Least Recently Used) Cache Replacement Algorithm | Computer Organisation & Architecture](https://www.youtube.com/watch?v=w32d1lD0Jb0) — Gate Smashers
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_5/computer_organization_and_architecture/lru-replacement
- Whole chapter: https://www.bctengineer.com/md/semester_5/computer_organization_and_architecture/chapter-6

## Question

Explain the Least Recently Used (LRU) replacement algorithm in case of hit and miss with suitable example.

## Short answer

LRU replaces the least recently used block. On a hit, the accessed block becomes most recent. On a miss with a free line, the new block is loaded as most recent. On a miss with a full cache, the least recent block is evicted. Example: 4-block cache with reference string 2,3,2,1,5,2,4,5,3,2,5,2 yields 6 hits, 6 misses, hit ratio 0.5.

## Answer

**LRU (Least Recently Used)** replaces the cache block that has not been used for the longest time. It uses temporal locality: a block used recently is likely to be used again soon. The hardware keeps an age (or use) counter for each line; on each access the age of the used line is reset and others are increased.

- **Hit:** the block is in the cache; no replacement. The block becomes the most recently used.
- **Miss with free line:** the block is loaded into a free line and becomes the most recently used.
- **Miss with cache full:** the least recently used block is removed and the new block is loaded.

#### Example: cache of 4 blocks, reference string 2, 3, 2, 1, 5, 2, 4, 5, 3, 2, 5, 2
```text
Ref  Result            Cache (most recent first)
2    Miss              [2]
3    Miss              [3, 2]
2    Hit               [2, 3]
1    Miss              [1, 2, 3]
5    Miss              [5, 1, 2, 3]
2    Hit               [2, 5, 1, 3]
4    Miss (evict 3)    [4, 2, 5, 1]
5    Hit               [5, 4, 2, 1]
3    Miss (evict 1)    [3, 5, 4, 2]
2    Hit               [2, 3, 5, 4]
5    Hit               [5, 2, 3, 4]
2    Hit               [2, 5, 3, 4]
```

Hits = 6, misses = 6, hit ratio = 6/12 = 0.50. When 4 was referenced the cache was full and the least recently used block was 3, so 3 was evicted; when 3 came back, block 1 was the least recently used, so 1 was evicted.

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. What happens on a hit in LRU?
   A. Block is replaced
   B. No replacement; the block becomes most recently used
   C. Oldest block removed
   D. Cache cleared
   Answer: B. A hit just updates recency. (Key point: Hit)

2. On a miss with a free line?
   A. LRU block evicted
   B. Block loaded into free line, becomes most recent
   C. Request ignored
   D. Random block evicted
   Answer: B. No eviction is needed. (Key point: Miss with free line)

3. In the example, which block is evicted when 3 returns after 4 and 5?
   A. Block 2
   B. Block 5
   C. Block 1
   D. Block 4
   Answer: C. Cache is [5,4,2,1] most recent first, so 1 is LRU. (Key point: Eviction)

4. How many hits and misses in the example?
   A. 4 hits, 8 misses
   B. 6 hits, 6 misses
   C. 8 hits, 4 misses
   D. 5 hits, 7 misses
   Answer: B. Hit ratio 6/12 = 0.50. (Key point: Counts)

## Related in Computer Organization and Architecture

- [Memory characteristics and LRU replacement](https://www.bctengineer.com/question.md?key=semester_5%2Fcomputer_organization_and_architecture%3Amemory-char-lru) — Computer Organization and Architecture, chapter 6
- [Mapping function and replacement algorithm](https://www.bctengineer.com/question.md?key=semester_5%2Fcomputer_organization_and_architecture%3Amapping-replacement) — Computer Organization and Architecture, chapter 6
- [Need for replacement algorithm in cache](https://www.bctengineer.com/question.md?key=semester_5%2Fcomputer_organization_and_architecture%3Areplacement-why) — Computer Organization and Architecture, chapter 6
- [Replacement algorithm in associative mapping](https://www.bctengineer.com/question.md?key=semester_5%2Fcomputer_organization_and_architecture%3Areplacement-assoc) — Computer Organization and Architecture, chapter 6
- [Associative mapping and replacement algorithms](https://www.bctengineer.com/question.md?key=semester_5%2Fcomputer_organization_and_architecture%3Aassociative-mapping) — Computer Organization and Architecture, chapter 6, asked 2×
- [Why direct mapping needs no replacement](https://www.bctengineer.com/question.md?key=semester_5%2Fcomputer_organization_and_architecture%3Adirect-no-replacement) — Computer Organization and Architecture, chapter 6, asked 2×

## Related in other subjects

- [LRU algorithm; page faults on string](https://www.bctengineer.com/question.md?key=semester_6%2Foperating_system%3Alru-page-faults-ref-string) — Operating System, chapter 4
- [Cache write policy and replacement algorithm](https://www.bctengineer.com/question.md?key=semester_6%2Fembedded_system%3Acache-write-policy-replacement) — Embedded System, chapter 4
- [Hits and faults: FIFO, LRU, Optimal](https://www.bctengineer.com/question.md?key=semester_6%2Foperating_system%3Ahits-faults-fifo-lru-optimal-3frames) — Operating System, chapter 4
- [Page faults: LRU, FIFO, Optimum](https://www.bctengineer.com/question.md?key=semester_6%2Foperating_system%3Apage-faults-lru-fifo-optimum) — Operating System, chapter 4