# 30 kW 240 V generator, 3% drop

Electric Machine Design · Chapter 5: DC Machine Design

- Asked in: 2072 Chaitra, 8 marks
- Answer checked by Claude Sonnet 5.5 on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_5/electric_machine_design/dc-generator-30kw-240v-3pct
- Whole chapter: https://www.bctengineer.com/md/semester_5/electric_machine_design/chapter-5

## Question

A design is required for a 30 kW, 4 pole, 900 rpm dc shunt generator, the full load terminal voltage being 240 V. Assume that the full load armature voltage is 3% of the terminal voltage. Calculate the main dimension of the machine. Given that: Maximum gap flux density = 0.85 Wb/m²; Specific electric loading = 20000 ampere conductor per metre; Field resistance = 120 Ω; Ratio of pole arc to pole pitch = 0.7; Field form factor = 0.7

## Short answer

Ia=127 A, E=247.2 V, Pa=31.39 kW. Co=117.4, D²L=0.01782 m³. Assuming square pole face, D=0.319 m, L=0.175 m.

## Answer

The main dimensions come from the **output equation of a dc machine** (A.K. Sawhney):

$$
P_a = C_0 D^2 L n, \qquad C_0 = \pi^2 B_{av}\, ac \times 10^{-3}\ \text{kW/(m}^3\text{ rps)}
$$

where $P_a$ = armature power (kW), $D$ = armature diameter, $L$ = core length (m), $n$ = speed (rps).

The full-load armature voltage **drop** $I_aR_a$ is 3% of terminal voltage. Field form factor $K_f = B_{av}/B_m = 0.7$ (equal to $\psi$). Since no length ratio is given, the standard assumption of a **square pole face** (L = pole arc) is used.

#### Step 1: Armature power from currents and emf
$$
\begin{aligned}
I_L &= \frac{30000}{240} = 125.0\ \text{A} \\
I_f &= \frac{240}{120} = 2.0\ \text{A} \\
I_a &= I_L + I_f = 127.0\ \text{A} \\
E &= V + I_aR_a = 240 + 0.03\times240 = 247.2\ \text{V} \\
P_a &= E I_a = 247.2\times127.0 = 31.39\ \text{kW}
\end{aligned}
$$

#### Step 2: Loadings and $D^2L$
$$
\begin{aligned}
B_{av} &= \psi B_m = 0.7\times0.85 = 0.595\ \text{Wb/m}^2 \\
C_0 &= \pi^2\times0.595\times20000\times10^{-3} = 117.4 \\
n &= 900/60 = 15\ \text{rps} \\
D^2L &= \frac{31.39}{117.4\times15} = 0.01782\ \text{m}^3
\end{aligned}
$$

#### Step 3: Square pole face
$$
L = \psi\frac{\pi D}{p} = \frac{0.7\pi D}{4} = 0.5498D
$$

$$
\begin{aligned}
D^3 &= \frac{0.01782}{0.5498} = 0.03241\ \text{m}^3 \\
D &= 0.3188\ \text{m} \\
L &= 0.5498\times0.3188 = 0.1753\ \text{m}
\end{aligned}
$$

#### Check
- Pole pitch $\tau = \pi D/4 = 0.250$ m; pole arc $= 0.7\tau = 0.1753$ m $= L$.
- Peripheral speed $= \pi Dn = 15.0$ m/s; frequency $= pn/2 = 30$ Hz. Both acceptable.

**Answer: Armature diameter $D \approx 0.319$ m, armature core length $L \approx 0.175$ m.**

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. What role does the field form factor Kf = 0.7 play here?
   A. It is the ratio of field current to armature current
   B. It is the efficiency of the field winding
   C. It equals Bav/Bm, so Bav = 0.7 x 0.85 = 0.595 Wb/m^2
   D. It is the stacking factor of the core
   Answer: C. Kf = Bav/Bm (equal to ψ here), so Bav = 0.595 Wb/m^2. (Key point: Field form factor)

2. With an armature drop of 3% of 240 V and Ia = 127 A, what is Pa?
   A. 30 kW
   B. 247.2 V x 127 A = 31.39 kW
   C. 240 x 127 = 30.48 kW
   D. 247.2 x 125 = 30.9 kW
   Answer: B. E = 240 + 0.03 x 240 = 247.2 V and Ia = 125 + 2 = 127 A, so Pa = E Ia = 31.39 kW. (Key point: Armature emf and power)

3. What is C0 for Bav = 0.595 and ac = 20000?
   A. C0 = 0.595 x 20000 = 11900
   B. C0 = π x 0.595 x 20 = 37.4
   C. C0 = π^2 x 0.85 x 20 = 167.8
   D. C0 = π^2 x 0.595 x 20000 x 10^-3 = 117.4
   Answer: D. C0 = π^2 Bav ac x 10^-3 = 9.87 x 0.595 x 20 = 117.4. (Key point: Output coefficient)

4. Since no length ratio is given, what assumption fixes L?
   A. Square pole face: L = pole arc = 0.5498D, giving D = 0.319 m and L = 0.175 m
   B. L equals the pole pitch
   C. L equals the armature diameter
   D. L is chosen from peripheral speed
   Answer: A. The standard assumption is L = pole arc = ψπD/p, which yields D = 0.319 m and L = 0.175 m. (Key point: Square pole face assumption)

## Close variants set in other exams

- [30 kW 240 V generator, 2.5% drop](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-30kw-240v-2-5pct) — Electric Machine Design, chapter 5, asked 3×
- [Main dimensions of 30 kW 220 V shunt generator](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-30kw-220v) — Electric Machine Design, chapter 5, asked 4×

## Related in Electric Machine Design

- [30 kW 240 V generator, square pole](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-30kw-240v-square) — Electric Machine Design, chapter 5, asked 2×
- [Armature dimensions of 50 kW shunt generator](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-50kw-armature) — Electric Machine Design, chapter 5
- [Armature size, 10 kW 900 rpm motor](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-motor-10kw-900rpm) — Electric Machine Design, chapter 5, asked 5×
- [Main dimensions of 600 kW square-pole generator](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-600kw-square) — Electric Machine Design, chapter 5
- [Main dimensions of 200 kW shunt generator](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-200kw) — Electric Machine Design, chapter 5
- [Armature size, 7.5 kW 1800 rpm motor](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-motor-7-5kw-1800rpm) — Electric Machine Design, chapter 5, asked 5×

## Related in other subjects

- [30 kW shunt generator: emf, copper loss, efficiency](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines%3Agen-shunt-30kw-loss-1000w) — Electrical Machines, chapter 3, asked 2×
- [30 kW shunt generator: emf, copper loss, efficiency (100 W)](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines%3Agen-shunt-30kw-loss-100w) — Electrical Machines, chapter 3, asked 2×
- [EMF, copper loss and efficiency of 30 kW shunt generator](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Ashunt-gen-30kw-200v-emf-losses) — Electrical Machines I, chapter 3
- [4-pole shunt generator, 3 kW at 120 V](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machine%3Ashunt-generator-4pole-wave-3kw) — Electrical Machine, chapter 3, asked 2×