# 600 kW generator: dimensions, poles, air gap

Electric Machine Design · Chapter 5: DC Machine Design

- Asked in: 2075 Asoj, 8 marks
- Answer checked by Claude Sonnet 5.5 on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_5/electric_machine_design/dc-generator-600kw-constraints
- Whole chapter: https://www.bctengineer.com/md/semester_5/electric_machine_design/chapter-5

## Question

Determine the main dimensions, number of poles and length of air gap of a 600 kW, 500 V, 900 rpm generator. Assume average gap density as 0.6 Wb/m² and ampere conductors per meter as 35,000 A/m. The ratio of pole arc to pole pitch is 0.75 and the efficiency is 91%. The following are the design constraints: peripheral speed ≤ 40 m/s, frequency of flux reversal ≤ 50 Hz, current per brush ≤ 400 A, and armature mmf per pole ≤ 7500 A. The mmf required for air gap is 50% of armature mmf and gap contraction factor is 1.15.

## Short answer

Using output equation, armature power 619.8 kW gives D²L=0.1994 m³. Constraints limit p=6, D=0.80 m, L≈0.31 m. Air-gap mmf 50% of armature mmf yields length about 5 mm.

## Answer

The main dimensions come from the **output equation of a dc machine** (A.K. Sawhney):

$$
P_a = C_0 D^2 L n, \qquad C_0 = \pi^2 B_{av}\, ac \times 10^{-3}\ \text{kW/(m}^3\text{ rps)}
$$

where $P_a$ = armature power (kW), $D$ = armature diameter, $L$ = core length (m), $n$ = speed (rps).

For a generator (Sawhney), $P_a = \dfrac{1+2\eta}{3\eta}P$.

#### Step 1: $D^2L$
$$
\begin{aligned}
P_a &= \frac{1+2\times0.91}{3\times0.91}\times600 = 619.8\ \text{kW} \\
C_0 &= \pi^2\times0.6\times35000\times10^{-3} = 207.3 \\
n &= 900/60 = 15\ \text{rps} \\
D^2L &= \frac{619.8}{207.3\times15} = 0.1994\ \text{m}^3
\end{aligned}
$$

#### Step 2: Number of poles
- Armature current $I_a \approx 600000/500 = 1200$ A (field current neglected).
- Frequency limit: $f = pn/2 \le 50 \Rightarrow p \le 50\times2/15 = 6.67$.
- Current per brush arm (lap winding, $a = p$): $2I_a/p \le 400 \Rightarrow p \ge 2\times1200/400 = 6$.

Only $p = 6$ meets both: $f = 6\times15/2 = 45$ Hz and current per brush arm $= 2400/6 = 400$ A. **Poles = 6.**

#### Step 3: Diameter limits
- Peripheral speed: $\pi D n \le 40 \Rightarrow D \le \dfrac{40}{\pi\times15} = 0.849$ m.
- Armature mmf per pole: $AT_a = \dfrac{ac\,\pi D}{2p} \le 7500 \Rightarrow D \le \dfrac{7500\times12}{35000\pi} = 0.819$ m.

Take **$D = 0.80$ m** (just inside both limits).

$$
L = \frac{D^2L}{D^2} = \frac{0.1994}{0.8^2} = 0.312\ \text{m}
$$

Check: $\pi Dn = 37.7$ m/s $< 40$; pole pitch $\tau = \pi\times0.8/6 = 0.419$ m; pole arc $= 0.75\tau = 0.314$ m (nearly square pole face with $L = 0.312$ m).

#### Step 4: Length of air gap
$$
\begin{aligned}
AT_a &= \frac{35000\times\pi\times0.8}{2\times6} = 7330\ \text{A} \\
AT_g &= 0.5\times7330 = 3665\ \text{A} \\
B_g &= \frac{B_{av}}{\psi} = \frac{0.6}{0.75} = 0.8\ \text{Wb/m}^2
\end{aligned}
$$

Using $AT_g = 800\,000\,B_g\,k_g\,l_g$ (since $1/\mu_0 \approx 8\times10^5$):

$$
l_g = \frac{3665}{800000\times0.8\times1.15} = 4.98\times10^{-3}\ \text{m} \approx 5\ \text{mm}
$$

**Answer: Poles = 6, $D = 0.80$ m, $L \approx 0.31$ m, air gap $l_g \approx 5$ mm.**

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. Which constraints fix p = 6?
   A. Frequency gives p >= 6 and brush current gives p <= 6.67
   B. Frequency gives p <= 6.67 and brush current (2Ia/p <= 400 A) gives p >= 6, so only p = 6 fits
   C. Peripheral speed fixes p = 6 directly
   D. Armature mmf gives p = 6 directly
   Answer: B. f = pn/2 <= 50 gives p <= 6.67; 2 x 1200/p <= 400 gives p >= 6. Hence 6 poles. (Key point: Choosing number of poles)

2. Which constraint is the tighter limit on D, and what D is chosen?
   A. Peripheral speed (0.849 m); D = 0.85 m
   B. Armature mmf per pole (0.819 m); D = 0.80 m, inside both limits
   C. Frequency; D = 0.5 m
   D. Brush current; D = 1.0 m
   Answer: B. Peripheral speed gives D <= 0.849 m and armature mmf gives D <= 0.819 m; D = 0.80 m satisfies both. (Key point: Limit on diameter)

3. How are the gap mmf and gap density found for the air-gap length?
   A. ATg = 0.5 ATa = 3665 A and Bg = Bav/ψ = 0.8 Wb/m^2
   B. ATg = 2 ATa and Bg = Bav = 0.6
   C. ATg = ATa and Bg = ψ Bav
   D. ATg = 0.5 ATa and Bg = ψ Bav = 0.45
   Answer: A. ATa = ac πD/2p = 7330 A, ATg = 50% of it, and the peak gap density Bg = Bav/ψ = 0.8. (Key point: Air-gap mmf and gap density)

4. Which expression gives the air-gap length?
   A. lg = ATg x 800000 x Bg
   B. lg = ATg Bg/(800000 kg)
   C. lg = 800000 Bg/ATg
   D. lg = ATg/(800000 Bg kg) = 3665/(800000 x 0.8 x 1.15), about 5 mm
   Answer: D. From ATg = 800000 Bg kg lg, lg = 4.98 mm, about 5 mm. (Key point: Air-gap length)

## Related in Electric Machine Design

- [1000 kW generator: dimensions, poles, air gap](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-1000kw-air-gap) — Electric Machine Design, chapter 5
- [Main dimensions and poles of 37 kW shunt motor](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-motor-37kw-poles) — Electric Machine Design, chapter 5, asked 3×
- [Main dimensions and poles of 40 kW shunt motor](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-motor-40kw-poles) — Electric Machine Design, chapter 5, asked 3×
- [Main dimensions of 5 kW generator (Bav 0.42)](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-5kw-bav-042) — Electric Machine Design, chapter 5, asked 4×
- [Main dimensions of 200 kW shunt generator](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-200kw) — Electric Machine Design, chapter 5
- [Main dimensions of 5 kW generator (Bav 0.40)](https://www.bctengineer.com/question.md?key=semester_5%2Felectric_machine_design%3Adc-generator-5kw-bav-040) — Electric Machine Design, chapter 5, asked 4×

## Related in other subjects

- [Iron ring current for 0.82 Wb air-gap flux](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machine%3Airon-ring-air-gap-0-82-wb) — Electrical Machine, chapter 1, asked 2×
- [Iron ring current for 0.8 Wb air-gap flux](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machine%3Airon-ring-air-gap-0-8-wb) — Electrical Machine, chapter 1, asked 2×
- [Air gap flux density in core with three windings](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Athree-winding-core-airgap-flux-density) — Electrical Machines I, chapter 1
- [Number of turns for iron ring with air gap](https://www.bctengineer.com/question.md?key=semester_4%2Felectrical_machines_i%3Airon-ring-1p25m-turns-0p5wb) — Electrical Machines I, chapter 1, asked 2×