---
title: "Intermediate Sal timber joist, 2.5 m span"
subject: "Design of Steel and Timber Structure"
chapter: 12
key: "semester_6/design_of_steel_and_timber_structure:timber-joist-sal-600mm"
source: https://www.bctengineer.com/q/semester_6/design_of_steel_and_timber_structure/timber-joist-sal-600mm
site: BCT Engineering
---

# Intermediate Sal timber joist, 2.5 m span

Design of Steel and Timber Structure · Chapter 12: Design of Flexure Member

- Asked in: 2079 Chaitra, 8 marks
- Video: [How to design timber joists | Check for Bending, shear & deflection.](https://www.youtube.com/watch?v=WzBFqlIlOVQ) — Structural Engineer Calcs
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_6/design_of_steel_and_timber_structure/timber-joist-sal-600mm
- Whole chapter: https://www.bctengineer.com/md/semester_6/design_of_steel_and_timber_structure/chapter-12

## Question

Design an intermediate Sal wood timber joist used in the roof of a hall from the following data:
Spacing of joist = 600 mm
Clear span of joist = 2.5 m
Dead load of roof covering = 2 kN/m²
Imposed load on roof = 1.5 kN/m²
The timber is of standard grade and used in inside location.

## Short answer

Use working stress design to IS 883. Provide 63 mm x 125 mm Sal joists at 600 mm centres. Bearing at supports 75 mm. Bending 10.92 N/mm², shear 0.53 N/mm², deflection 9.5 mm.

## Answer

**Approach.** Working stress design of a timber joist (beam) to IS 883:1994 cl. 7.5. Checks: bending strength, horizontal shear, bearing stress at the supports and deflection. Self-weight is included (cl. 7.5.9.4).

#### Data and permissible stresses

Clear span $= 2.50$ m, bearing length $= 75$ mm.

**Species:** Sal (Shorea robusta), Group A. **Location:** inside. **Grade:** Grade I (standard) (Table 1 values are for Grade I).

Permissible stresses (IS 883:1994 Table 1, inside location):

| Property | Table 1 value (N/mm²) | Used (N/mm²) |
|---|---|---|
| Bending / tension along grain $f_b$ | 16.9 | 16.90 |
| Compression parallel to grain $f_{cp}$ | 10.6 | 10.60 |
| Compression perpendicular to grain $f_{cn}$ | 4.6 | 4.60 |
| Horizontal shear $H$ | 0.94 | 0.94 |
| Modulus of elasticity $E$ | 12670 | 12670 |

#### Loads and effective span

Joist spacing 0.6 m. Dead load of roof covering $2.0$ kN/m²; imposed load $1.5$ kN/m². Load per metre of joist $= (2.0 + 1.5)\times0.6 = 2.10$ kN/m (plus self-weight). The joists are inside, so inside stresses are used; a bearing of 75 mm on the wall is assumed (cl. 7.5.8.1).

Effective span (cl. 7.5.2): clear span $+$ bearing length $= 2500 + 75 = 2575$ mm $= 2.575$ m.

#### Trial section

Width not less than 50 mm or $L/50 = 52$ mm (cl. 7.5.5), and depth not more than 3 times the width without lateral stiffening (cl. 7.5.6). Try **63 mm × 125 mm**.

Self-weight $= 0.063\times0.125\times805\times9.81/1000 = 0.062$ kN/m (density 805 kg/m³). Total UDL $w = 2.100 + 0.062 = 2.162$ kN/m.

Reaction $R = wL/2 = 2.78$ kN (shear $V = 2.78$ kN); maximum bending moment $M = wL^2/8 = 1.79$ kN·m.

#### Bending

$$
\begin{aligned} Z &= \frac{bd^2}{6} = \frac{63\times125^2}{6} = 0.164\times10^6\ \text{mm}^3 \\ f_{ab} &= \frac{M}{Z} = \frac{1.79\times10^6}{0.164\times10^6} = 10.92\ \text{N/mm}^2 \end{aligned}
$$

Depth $\le 300$ mm, so no form factor is applied: $f_b = 16.90$ N/mm².

$f_{ab} = 10.92 < 16.90$ N/mm². **Safe.**

#### Horizontal shear (cl. 7.5.7)

$$
H = \frac{3V}{2bd} = \frac{3\times2784}{2\times63\times125} = 0.530\ \text{N/mm}^2 \le 0.94\ \text{N/mm}^2
$$
(No reduction is taken for loads near the supports, which is on the safe side.) **Safe.**

#### Bearing (cl. 7.5.8)

$$
f_{cn}' = \frac{R}{b\times\text{bearing}} = \frac{2784}{63\times75} = 0.59\ \text{N/mm}^2 < f_{cn} = 4.60\ \text{N/mm}^2
$$
The permissible stress perpendicular to the grain applies for any bearing length at the ends of a member. **Safe.**

#### Deflection (cl. 7.5.9)

$E = 12670$ N/mm², $I = bd^3/12 = 10.25\times10^6$ mm⁴. Limit $= L/240 = 10.73$ mm (members not carrying brittle finishes).

$$
\delta = \frac{5wL^4}{384EI} = 9.53\ \text{mm} < \frac{L}{240} = 10.73\ \text{mm}
$$
**Safe.**

#### Answer

Provide Sal joists **63 mm × 125 mm** at 600 mm centres (Grade I (standard), inside), with a bearing of at least 75 mm at each support. $f_{ab} = 10.92$ N/mm², $H = 0.53$ N/mm², $\delta = 9.5$ mm.

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. How is the UDL on one joist found from the roof loads?
   A. (2.0 + 1.5) x span = 8.75 kN/m
   B. (2.0 + 1.5) x 0.6 = 2.10 kN/m plus self-weight
   C. 2.0 x 0.6 only, since imposed load is ignored
   D. (2.0 + 1.5) / 0.6 = 5.83 kN/m
   Answer: B. Area loads in kN/m^2 are multiplied by the joist spacing to get kN/m, then the joist self-weight is added. (Key point: Load per metre of joist)

2. Why is no form factor applied to the permissible bending stress of the 63 x 125 joist?
   A. Because the depth is not more than 300 mm
   B. Because Sal is a Group A species
   C. Because the joist is inside
   D. Because the load is a UDL
   Answer: A. The depth factor of cl. 7.5.4 applies only to depths over 300 mm, so f_b stays at 16.90 N/mm^2. (Key point: No form factor)

3. With M = 1.79 kN.m and Z = bd^2/6 = 0.164 x 10^6 mm^3, what is the result of the bending check?
   A. f_ab = 10.92 N/mm^2 < 16.90, safe
   B. f_ab = 10.92 N/mm^2 > 0.94, unsafe
   C. f_ab = 0.53 N/mm^2 < 16.90, safe
   D. f_ab = 21.8 N/mm^2 > 16.90, unsafe
   Answer: A. f_ab = M/Z = 1.79e6/0.164e6 = 10.92 N/mm^2, which is below the permissible 16.90 N/mm^2. (Key point: Bending check)

4. What deflection limit is used and does the joist satisfy it?
   A. L/360 = 7.2 mm, fails with 9.53 mm
   B. L/240 = 10.73 mm, passes with 9.53 mm
   C. L/240 = 10.73 mm, fails with 9.53 mm
   D. L/180 = 14.3 mm, passes with 9.53 mm
   Answer: B. For members without brittle finishes the limit is span/240 = 2575/240 = 10.73 mm, and the computed 5wL^4/384EI is 9.53 mm. (Key point: Deflection limit)

## Related in Design of Steel and Timber Structure

- [Sal timber beam, 2.5 m span, 20 kN/m](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Atimber-beam-sal-2-5m-20knm) — Design of Steel and Timber Structure, chapter 12
- [Sal select grade beam, 15 kN/m, 4 m](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Atimber-beam-sal-15knm-4m) — Design of Steel and Timber Structure, chapter 12
- [RCC floor joist design, 15 m x 6 m hall](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Afloor-joist-15x6-rcc) — Design of Steel and Timber Structure, chapter 7
- [Intermediate beam for 15 m x 6 m hall](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Aintermediate-beam-15x6-110mm) — Design of Steel and Timber Structure, chapter 7, asked 2×
- [Intermediate beam for 18 m x 6 m office hall](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Aoffice-hall-18x6-intermediate-beam) — Design of Steel and Timber Structure, chapter 7
- [Sal timber column, 50 kN, 4 m](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Atimber-column-sal-50kn-4m) — Design of Steel and Timber Structure, chapter 11

## Related in other subjects

- [Timber joist dimensions under UDL and point load](https://www.bctengineer.com/question.md?key=semester_3%2Fstrength_of_materials%3Atimber-joist-5kn-m-15kn) — Strength of Materials, chapter 7
- [Beam with torsion, 4.5 m clear span](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Abeam-with-torsion-4-5-m) — Design of RCC Structure, chapter 5
- [Legal and standard axle load; rigid stresses; joint spacing](https://www.bctengineer.com/question.md?key=semester_7%2Ftransportation_engineering_ii%3Alegal-standard-axle-stresses-contraction-joint) — Transportation Engineering II, chapter 2
- [Rate analysis: sal wood door/window frame per m³](https://www.bctengineer.com/question.md?key=semester_7%2Festimating_and_costing%3Arate-sal-wood-frame) — Estimating and Costing, chapter 4, asked 3×
