# Break-even hours for two pumps

Engineering Economics · Chapter 1: Introduction

- Asked in: 2070 Magh, 8 marks
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_6/engineering_economics/breakeven-hours-khasa-sarvo-pump
- Whole chapter: https://www.bctengineer.com/md/semester_6/engineering_economics/chapter-1

## Question

Calculate break-even hours of operation per year to become cost equal and recommend the economic pump if it is to be operated 5 hours daily at full load.
|  | KHASA Pump | SARVO Pump |
|---|---|---|
| Capacity | 100 hp | 100 hp |
| Purchase cost (Rs.) | 5,00,000 | 10,00,000 |
| Tax per year (Rs.) | 10,000 | 15,000 |
| Maintenance cost per year (Rs.) | 36,500 | 29,200 |
| Efficiency | 80% | 90% |
| Life, year | 5 | 5 |
| Salvage value | 20% of purchase cost for both |  |
| MARR | 20% per year |  |
| Electricity cost | Rs. 16/kwh |  |

## Short answer

Fixed costs: Khasa Rs 200,252, Sarvo Rs 351,704; energy cost/hour: Rs 1,492 and Rs 1,326.22. Equating: 200252+1492h = 351704+1326.22h gives break-even 914 hours/year. At 5h/day (1,825 h) Sarvo saves ~Rs 1.51 lakh/year and is recommended.

## Answer

#### Approach
Compare the annual cost of each pump as a function of operating hours h per year: Annual cost = fixed annual cost + (energy cost per hour) × h. Set them equal to get the break-even hours.

#### Assumptions
1 hp = 0.746 kW; the motor draws power = rated output ÷ efficiency (full load); interest rate = MARR = 20%; capital cost is converted to an annual figure by capital recovery with salvage.

Capital recovery (CR) = (P − S)(A/P, 20%, 5) + S(0.20), where (A/P, 20%, 5) = 0.33438

#### Annual fixed cost
| Item | KHASA | SARVO |
|---|---|---|
| P (Rs) | 500,000 | 1,000,000 |
| S = 20% of P (Rs) | 100,000 | 200,000 |
| CR (Rs/yr) | 400,000×0.33438 + 100,000×0.2 = 153,752 | 800,000×0.33438 + 200,000×0.2 = 307,504 |
| Tax (Rs/yr) | 10,000 | 15,000 |
| Maintenance (Rs/yr) | 36,500 | 29,200 |
| **Fixed cost (Rs/yr)** | **200,252** | **351,704** |

#### Energy cost per hour
- KHASA: 100 × 0.746 / 0.80 = 93.25 kW; × Rs 16 = **Rs 1,492 per hour**
- SARVO: 100 × 0.746 / 0.90 = 82.89 kW; × Rs 16 = **Rs 1,326.22 per hour**

#### Break-even hours
200,252 + 1,492 h = 351,704 + 1,326.22 h
165.78 h = 151,452
**h = 913.6 hours per year**

#### Decision for 5 hours daily
Hours = 5 × 365 = 1,825 h per year (> 913.6 h).
- KHASA: 200,252 + 1,492 × 1,825 = Rs 2,923,152 per year
- SARVO: 351,704 + 1,326.22 × 1,825 = Rs 2,772,059 per year

**Answer: Break-even = about 914 hours per year. At 1,825 hours the SARVO pump is cheaper (Rs 2.77 million vs 2.92 million per year, saving about Rs 151,000), so SARVO is recommended.** SARVO is better whenever it runs more than about 914 hours per year.

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. The approach used for break-even hours is:
   A. Equate purchase costs
   B. Equate efficiencies
   C. Equate salvage values
   D. Equate annual cost = fixed annual cost + hourly energy cost x h for both pumps
   Answer: D. The two annual cost lines cross at the break-even hours. (Key point: Approach)

2. Energy cost per hour for KHASA is:
   A. 100 x 0.746 / 0.80 x 16 = Rs 1,492
   B. 100 x 0.746 x 0.80 x 16 = Rs 954
   C. 100 x 16 = Rs 1,600
   D. 100 x 0.746 / 0.90 x 16 = Rs 1,326
   Answer: A. Input power = output / efficiency. (Key point: Energy cost)

3. Annual capital cost uses:
   A. P x 0.20 only
   B. CR = (P - S)(A/P, 20%, 5) + S(0.20)
   C. (P + S)/5
   D. P/5
   Answer: B. Capital recovery with salvage at MARR 20%. (Key point: Capital recovery)

4. At 5 h/day (1,825 h/yr), which is cheaper and why?
   A. Both equal
   B. KHASA, since its fixed cost is lower
   C. SARVO, since 1,825 h exceeds the break-even of about 914 h
   D. KHASA, since 1,825 h exceeds break-even
   Answer: C. Above break-even hours, the lower running cost (higher efficiency) pump wins. (Key point: Decision)

## Related in Engineering Economics

- [Explain break-even analysis and its significance](https://www.bctengineer.com/question.md?key=semester_6%2Fengineering_economics%3Abreakeven-significance) — Engineering Economics, chapter 1, asked 3×
- [Break-even volume of a cable company](https://www.bctengineer.com/question.md?key=semester_6%2Fengineering_economics%3Abreakeven-cable-manufacturing-5000) — Engineering Economics, chapter 1
- [Break-even units and output for desired profit](https://www.bctengineer.com/question.md?key=semester_6%2Fengineering_economics%3Abreakeven-units-profit-50000) — Engineering Economics, chapter 1
- [CFL versus filament bulb economic comparison](https://www.bctengineer.com/question.md?key=semester_6%2Fengineering_economics%3Acfl-vs-filament-bulb) — Engineering Economics, chapter 4
- [ERR to recommend best of A, B, C](https://www.bctengineer.com/question.md?key=semester_6%2Fengineering_economics%3Aerr-recommend-best-abc-e20) — Engineering Economics, chapter 4
- [Payback period to recommend best of A, B, C](https://www.bctengineer.com/question.md?key=semester_6%2Fengineering_economics%3Apayback-recommend-abc-2a) — Engineering Economics, chapter 4

## Related in other subjects

- [Break-even cost comparison of three sites](https://www.bctengineer.com/question.md?key=semester_6%2Findustrial_engineering_and_management%3Abreak-even-analysis-plant-location) — Industrial Engineering and Management, chapter 2
- [Break-even analysis for a startup](https://www.bctengineer.com/question.md?key=semester_7%2Fentrepreneurship_development%3Abreak-even-analysis-numerical) — Entrepreneurship Development, chapter 5
- [Installed capacity, energy and daily peaking reservoir (2079)](https://www.bctengineer.com/question.md?key=semester_7%2Fhydropower_engineering%3Aror-capacity-plant-factor-18cumec-peaking-79) — Hydropower Engineering, chapter 3, asked 2×
- [Installed capacity, energy and daily peaking reservoir (2072)](https://www.bctengineer.com/question.md?key=semester_7%2Fhydropower_engineering%3Aror-capacity-plant-factor-18cumec-peaking-72) — Hydropower Engineering, chapter 3, asked 2×