# Semi-modular pipe outlet design, flexibility 0.9

Irrigation and Drainage Engineering · Chapter 7: Regulating Structures

- Asked in: 2075 Bhadra, 8 marks
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_6/irrigation_and_drainage_engineering/semimodular-pipe-outlet-flexibility-09
- Whole chapter: https://www.bctengineer.com/md/semester_6/irrigation_and_drainage_engineering/chapter-7

## Question

A distributary channel having bed width 5.0 m, full supply depth of 1.20 m carries 3.0 cumec of water. A semi modular pipe outlet in this channel has a command area of 15 ha growing rice with a kor depth 20 cm and kor period of 3 weeks. Determine the size of the outlet and set it for sub proportionality with a flexibility of 0.9. Assume length of pipe as 3.0 m and friction factor as 0.03.

## Short answer

Required discharge q = (15 ha × 0.20 m)/(3 weeks) = 0.01653 m³/s. For flexibility 0.9, set H = 0.40 m (centre 0.80 m above bed). Pipe diameter from head loss equation: adopt 110 mm, length 3.0 m, giving about 17.5 l/s.

## Answer

A semi-modular pipe outlet discharges freely, so its discharge depends on the head $H$ between the distributary water level and the centre of the pipe: $q = K H^{m}$ with $m = 1/2$. The required discharge fixes the pipe size, and the flexibility fixes its setting (level).

#### 1. Discharge required
Kor depth $\Delta = 0.20$ m over the period $T = 3$ weeks $= 21\times86400 = 1\,814\,400$ s; area $A = 15$ ha $= 150\,000$ m²:
$$
q = \frac{A\,\Delta}{T} = \frac{150000\times0.20}{1814400} = 0.01653\ \text{m}^3/\text{s} = 16.5\ \text{l/s}
$$

#### 2. Setting for flexibility $F = 0.9$
For the outlet $q = KH^{m}$ and for the distributary $Q = kD^{n}$:
$$
F = \frac{dq/q}{dQ/Q} = \frac{m}{n}\,\frac{D}{H}
$$
For a pipe outlet $m = 1/2$, and for the distributary channel (wide, $B/D = 5/1.2 \approx 4$) $n = 5/3$:
$$
\frac{H}{D} = \frac{m}{n\,F} = \frac{0.5}{(5/3)\times0.9} = 0.333 \Rightarrow H = 0.333\times1.2 = 0.40\ \text{m}
$$
Centre of the pipe below FSL $= 0.40$ m, i.e. $1.2 - 0.40 = 0.80$ m above the distributary bed. ($F < 1$ gives a **sub-proportional** outlet; for proportionality the setting would be $H/D = 0.3$.)

#### 3. Size of the pipe
Head loss through a pipe of length $L = 3$ m with entry loss $0.5\dfrac{v^2}{2g}$, friction $f = 0.03$ and exit (velocity head) loss:
$$
H = \left(1 + 0.5 + \frac{fL}{d}\right)\frac{v^2}{2g}, \qquad q = \frac{\pi}{4}d^2 v
$$
Solving by trial with $H = 0.40$ m and $q = 0.01653$ m³/s gives $d = 0.107$ m. Adopt a **110 mm** diameter pipe. Check: $\left(1.5 + \dfrac{0.03\times3}{0.11}\right) = 2.32$, $v = \sqrt{\dfrac{2\times9.81\times0.40}{2.32}} = 1.84$ m/s, $q = \dfrac{\pi}{4}(0.11)^2\times1.84 = 17.5$ l/s, which is slightly above the 16.5 l/s required.

**Answer:** pipe diameter 110 mm (theoretical 107 mm), length 3.0 m, with its centre set 0.40 m below FSL (0.80 m above the distributary bed), giving $F = 0.9$ and a discharge of about 17.5 l/s.

```text
 FSL ~~~~~~~~~~~~~~~~~~~~~~~~
                  H = 0.40 m          water course
      D = 1.2 m   --pipe 110 mm, L = 3 m-->  free outfall
 bed ___________  0.80 m above bed
```

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. How is the outlet discharge computed?
   A. q = A Δ/T = 150000 x 0.20 / (21 x 86400) = 16.5 l/s
   B. q = A/T = 150000/21 days
   C. q = Δ/T x 3 m
   D. q = 3.0 m³/s x 15/100
   Answer: A. Kor depth over the area divided by the kor period in seconds gives 0.01653 m³/s. (Key point: Required discharge)

2. For q = K sqrt(D - s), what head H over the pipe centre gives F = 0.9 with D = 1.2 m?
   A. H = D = 1.2 m
   B. H = 2FD = 2.16 m
   C. H = D/(2F) = 0.667 m
   D. H = D F = 1.08 m
   Answer: C. F = D/(2H), so H = D/(2F) = 1.2/1.8 = 0.667 m. (Key point: Head for given flexibility)

3. Where is the pipe centre set above the distributary bed?
   A. 0.667 m above the bed
   B. At the bed level
   C. 1.2 m above the bed
   D. s = D - H = 0.53 m above the bed, i.e. 0.67 m below FSL
   Answer: D. The pipe centre is H below FSL, so s = 1.2 - 0.667 = 0.533 m above the bed. (Key point: Setting of the pipe)

4. What does a flexibility of 0.9 indicate?
   A. Hyper-proportional outlet
   B. Sub-proportional outlet
   C. Proportional outlet
   D. Non-modular outlet
   Answer: B. F < 1 means the outlet discharge changes by a smaller fraction than the distributary discharge. (Key point: Meaning of F < 1)

## Related in Irrigation and Drainage Engineering

- [Non-modular, semi-modular outlet; module requirements](https://www.bctengineer.com/question.md?key=semester_6%2Firrigation_and_drainage_engineering%3Anonmodular-semimodular-working-module-requirements) — Irrigation and Drainage Engineering, chapter 7
- [Outlet, requirements, modular vs semi-modular](https://www.bctengineer.com/question.md?key=semester_6%2Firrigation_and_drainage_engineering%3Aoutlet-requirements-modular-distinction) — Irrigation and Drainage Engineering, chapter 7
- [Balancing depth: bed width 20 m](https://www.bctengineer.com/question.md?key=semester_6%2Firrigation_and_drainage_engineering%3Abalancing-depth-bed20-cut15-fill2) — Irrigation and Drainage Engineering, chapter 3, asked 3×
- [Pipe outlet minimum water level, 50 lps](https://www.bctengineer.com/question.md?key=semester_6%2Firrigation_and_drainage_engineering%3Apipe-outlet-min-water-level-50lps) — Irrigation and Drainage Engineering, chapter 7
- [Storage capacity, depth and water at outlet](https://www.bctengineer.com/question.md?key=semester_6%2Firrigation_and_drainage_engineering%3Astorage-capacity-wheat-field-efficiency) — Irrigation and Drainage Engineering, chapter 2
- [Outlet discharge: wheat and rice, 10000 ha](https://www.bctengineer.com/question.md?key=semester_6%2Firrigation_and_drainage_engineering%3Akor-outlet-discharge-wheat-rice-10000ha) — Irrigation and Drainage Engineering, chapter 2

## Related in other subjects

- [Channel earthwork and land area, bed 4 m](https://www.bctengineer.com/question.md?key=semester_7%2Festimating_and_costing%3Achannel-land-acquisition-f) — Estimating and Costing, chapter 6, asked 2×
- [Contraction and bed rise, 3.5 m channel (1.2 m depth)](https://www.bctengineer.com/question.md?key=semester_4%2Fhydraulics%3Acontraction-bed-rise-3-5m-wide-1-2m-depth) — Hydraulics, chapter 7
- [Contraction and bed rise, 3.5 m channel (1 m depth)](https://www.bctengineer.com/question.md?key=semester_4%2Fhydraulics%3Acontraction-bed-rise-3-5m-wide-1m-depth) — Hydraulics, chapter 7, asked 2×
- [Runoff from a 20 ha built-up area](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Arunoff-builtup-area-20ha) — Sanitary Engineering, chapter 2