---
title: "BOD of Bagmati sample at 30°C"
subject: "Sanitary Engineering"
chapter: 5
key: "semester_6/sanitary_engineering:bod-thapathali-4day-30c"
source: https://www.bctengineer.com/q/semester_6/sanitary_engineering/bod-thapathali-4day-30c
site: BCT Engineering
---

# BOD of Bagmati sample at 30°C

Sanitary Engineering · Chapter 5: Characteristics and Examination of Wastewater

- Asked in: 2075 Baisakh, 8 marks
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_6/sanitary_engineering/bod-thapathali-4day-30c
- Whole chapter: https://www.bctengineer.com/md/semester_6/sanitary_engineering/chapter-5

## Question

5 ml of a sewage sample taken under the Thapathali bridge of Bagmati river was pipetted into a 300 ml capacity BOD bottle which was then completely filled with dilution water. The DO concentration of this mixture is tested and found to be 9.2 mg/l. Now it is kept in the incubator maintained at 25°C for a period of 7 days. The DO concentration after incubation is found to be 5.3 mg/l. Adopting base 10 value of K as 0.1/d, determine the 4 day BOD of sewage at 30°C in Bagmati river at that particular location.

## Short answer

7-day BOD at 25°C from dilution test is 234 mg/L. Using K20=0.1/day and θ=1.047, ultimate BOD=269.5 mg/L. Then 4-day BOD at 30°C (K30=0.1583/day) = 206.8 mg/L.

## Answer

#### Step 1: BOD measured in the test (7 days at 25°C)
Dilution: 5 mL of sample in a 300 mL bottle, so the decimal fraction is

$$
P=\frac{5}{300}=0.0167
$$

$$
BOD_7^{25}=\frac{D_1-D_2}{P}=\frac{9.2-5.3}{0.0167}=234\ \text{mg/L}
$$

#### Step 2: Ultimate BOD
Here $K=0.1$ day⁻¹ (base 10) is taken as the rate constant at 20°C; the temperature coefficient is $\theta=1.047$. At 25°C:

$$
K_{25}=0.1\times1.047^{5}=0.1258\ \text{day}^{-1}
$$

$$
L=\frac{BOD_7}{1-10^{-K_{25}t}}=\frac{234}{1-10^{-0.8807}}=269.5\ \text{mg/L}
$$

#### Step 3: 4-day BOD at 30°C
$$
\begin{aligned}
K_{30}&=0.1\times1.047^{10}=0.1583\ \text{day}^{-1}\\
BOD_4^{30}&=L\left(1-10^{-K_{30}\times4}\right)=269.5\left(1-10^{-0.6332}\right)=206.8\ \text{mg/L}
\end{aligned}
$$

**Answer: 4-day BOD at 30°C = 206.8 mg/L** (ultimate BOD = 269.5 mg/L).

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. For 5 mL sample in a 300 mL bottle, what is P?
   A. 5/300 = 0.0167
   B. 300/5 = 60
   C. 5/295 = 0.017 of dilution water
   D. 0.5
   Answer: A. P = volume of sample / volume of mixture. (Key point: Dilution fraction)

2. How is the measured BOD calculated?
   A. (D1 - D2) x P = 0.065 mg/L
   B. (D1 - D2)/P = (9.2 - 5.3)/0.0167 = 234 mg/L
   C. D2/P = 317 mg/L
   D. (D1 + D2)/P = 870 mg/L
   Answer: B. BOD = DO drop divided by decimal dilution. (Key point: Measured BOD)

3. Why is K25 used to get L from the 7-day test?
   A. Because the bottle is 300 mL
   B. Because 7 days equals 25 hours
   C. The test was incubated at 25°C, so K = 0.1 at 20°C must be corrected to 25°C
   D. Because K is always taken at 25°C
   Answer: C. K25 = 0.1 x 1.047^5 = 0.1258; L = 234/(1 - 10^(-0.8807)) = 269.5 mg/L. (Key point: Ultimate BOD step)

4. What is the 4-day BOD at 30°C?
   A. About 234 mg/L
   B. About 270 mg/L
   C. About 100 mg/L
   D. About 207 mg/L
   Answer: D. With K30 = 0.1583, y4 = 269.5 (1 - 10^(-0.6332)) = 206.8 mg/L. (Key point: Final answer)

## Related in Sanitary Engineering

- [Sewage sampling and BOD dilution method](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Asampling-bod-dilution) — Sanitary Engineering, chapter 5
- [1-day BOD 300 mg/l to 5-day at 30°C](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Abod-1day-300-to-5day-30c) — Sanitary Engineering, chapter 5
- [5-day BOD and kg BOD in 3.2 ML](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Abod-dilution-2p5-in-250-7p8) — Sanitary Engineering, chapter 5, asked 2×
- [BOD5 and ultimate BOD, 5% dilution](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Abod-dilution-5pct-blank) — Sanitary Engineering, chapter 5
- [BOD test by dilution method](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Abod-determination-dilution-method) — Sanitary Engineering, chapter 5, asked 2×
- [5-day BOD and kg BOD in 5 ML](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Abod-dilution-2p5-in-250-8mg) — Sanitary Engineering, chapter 5, asked 2×

## Related in other subjects

- [pH of mixture: 700 ml pH 6 and 500 ml pH 8](https://www.bctengineer.com/question.md?key=semester_5%2Fwater_supply_engineering%3Aph-mix-c76) — Water Supply Engineering, chapter 4
- [pH of mixture: 400 ml pH 6 and 700 ml pH 8](https://www.bctengineer.com/question.md?key=semester_5%2Fwater_supply_engineering%3Aph-mix-c69) — Water Supply Engineering, chapter 4
- [Monthly progress report: Bagmati Bridge](https://www.bctengineer.com/question.md?key=semester_5%2Fcommunication_english%3Amonthly-progress-report-bagmati-bridge) — Communication English, chapter 7
- [Ca and Mg concentration, alkalinity (300 mg/l hardness)](https://www.bctengineer.com/question.md?key=semester_5%2Fwater_supply_engineering%3Ahardness-ca-mg-equal-300) — Water Supply Engineering, chapter 4, asked 2×
