title: "Separate sewer, 0.70 full, 100000 persons"
subject: "Sanitary Engineering"
chapter: 3
key: "semester_6/sanitary_engineering:sewer-0p7-full-100000"
source: https://www.bctengineer.com/q/semester_6/sanitary_engineering/sewer-0p7-full-100000
site: BCT Engineering
---

# Separate sewer, 0.70 full, 100000 persons

Sanitary Engineering · Chapter 3: Design and Construction of Sewers

- Asked in: 2069 Bhadra, 8 marks
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_6/sanitary_engineering/sewer-0p7-full-100000
- Whole chapter: https://www.bctengineer.com/md/semester_6/sanitary_engineering/chapter-3

## Question

Design a circular sewer running 0.70 full at maximum discharge for a town provided with the separate system serving a population of 100000 persons. Water is supplied from the water works at a rate of 200 liters per capita per day. Take a constant value of n = 0.013 at all depths of flow. The permissible slope is 1 in 600. Take a peak factor of 2.25.

## Short answer

Peak flow = 0.4167 m³/s. Using Q/Q_f=0.8372 at 0.7 depth, Q_f=0.4977 m³/s; from Manning's, D=0.776 m (adopt 825 mm). At design flow, the sewer runs about 0.62 full with v ≈ 1.19 m/s.

## Answer

#### Design flow
Assume 80% of the water supplied reaches the sewer. Peak factor = 2.25.

$$
Q_{max}=\frac{100000\times200\times0.8\times2.25}{86400\times1000}=0.4167\ \text{m}^3/\text{s}
$$

Data: $S=1/600$, $n=0.013$ (constant at all depths), depth ratio $d/D=0.70$.

For $d/D=0.7$: $\theta = 2\cos^{-1}(1-2d/D)=227.16^\circ$, $A/A_f=\dfrac{\theta-\sin\theta}{2\pi}=0.7477$, $R/R_f=1-\dfrac{\sin\theta}{\theta}=1.1849$, so $v/v_f=(R/R_f)^{2/3}=1.1198$ and $Q/Q_f=(A/A_f)(v/v_f)=0.8372$ (n taken constant).

#### Size of the sewer
Discharge when running full:

$$
Q_f=\frac{Q}{Q/Q_f}=\frac{0.4167}{0.8372}=0.4977\ \text{m}^3/\text{s}
$$

Manning's formula for a full circular pipe, $Q_f=\dfrac{0.3117}{n}D^{8/3}S^{1/2}$, with $S=0.00167$ and $n=0.013$:

$$
D=\left(\frac{Q_f\,n}{0.3117\,S^{1/2}}\right)^{3/8}=\left(\frac{0.4977\times0.013}{0.3117\times0.04082}\right)^{3/8}=0.776\ \text{m}
$$

Adopt the next standard size, **D = 825 mm**.

#### Check of velocity and capacity
For the adopted pipe: $v_f=\dfrac{0.3969}{n}D^{2/3}S^{1/2}=1.096$ m/s and $Q_f=0.5861$ m³/s.

$$
\begin{aligned}
v_{0.7}&=v_f\times(v/v_f)=1.096\times1.1198=1.23\ \text{m/s}\\
Q_{capacity}&=Q_f\times(Q/Q_f)=0.5861\times0.8372=0.4907\ \text{m}^3/\text{s}\ (\ge 0.4167)
\end{aligned}
$$

At the design flow, $Q/Q_f=0.4167/0.5861=0.711$, which gives $d/D\approx0.62$ and $v/v_f\approx1.086$, so $v\approx1.19$ m/s.

The velocity at maximum flow, about 1.2 m/s, lies between the minimum (0.6 m/s) and the maximum non-scouring limit (3.0 m/s), so it is satisfactory.

**Answer: Provide a circular sewer of D = 825 mm at slope 1 in 600** (computed diameter 0.776 m runs exactly 0.7 full). The adopted pipe can carry 0.4907 m³/s at 0.7 depth; at Q = 0.4167 m³/s it runs about 0.62 full with v ≈ 1.19 m/s.

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. What is Q_max for 100,000 people at 200 lpcd, 80% to sewer, peak factor 2.25?
   A. 0.1852 m3/s
   B. 0.4167 m3/s
   C. 0.5208 m3/s
   D. 1.0417 m3/s
   Answer: B. 100000 x 200 x 0.8 x 2.25 / 86400000 = 0.4167 m3/s. (Key point: Design flow)

2. With constant n at d/D = 0.7, the ratios are
   A. A/A_f = 0.7, v/v_f = 1.0, Q/Q_f = 0.7
   B. A/A_f = 0.8372, v/v_f = 0.7477, Q/Q_f = 1.1198
   C. A/A_f = 0.7477, v/v_f = 1.1198, Q/Q_f = 0.8372
   D. A/A_f = 0.7477, v/v_f = 0.7477, Q/Q_f = 0.559
   Answer: C. Q/Q_f is the product of A/A_f and v/v_f; velocity at 0.7 depth exceeds full velocity because R is larger. (Key point: Proportionate values at 0.7 depth)

3. Why is velocity at 0.7 depth greater than at full flow (v/v_f = 1.12)?
   A. The hydraulic radius is larger than at full flow (R/R_f = 1.185)
   B. The area is larger than full area
   C. The slope increases in a partly full sewer
   D. Manning's n decreases at partial depth
   Answer: A. R = A/P peaks near 0.81 depth, so velocity at partial depth can exceed full velocity when n is constant. (Key point: Why v exceeds v_f)

4. The computed D is 0.776 m. What is provided and why?
   A. 700 mm, the nearest smaller standard size
   B. 900 mm, the next standard size; capacity 0.619 m3/s exceeds 0.4167
   C. 776 mm exactly
   D. 1200 mm since peak factor is high
   Answer: B. Adopt the next larger standard size, then verify velocity (1.30 m/s) and capacity. (Key point: Selecting final size)

## Close variants set in other exams

- [Separate sewer, 0.6 full, 250000 persons](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Asewer-0p6-full-250000) — Sanitary Engineering, chapter 3, asked 2×

## Related in Sanitary Engineering

- [Design discharge, separate and combined](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Adesign-discharge-separate-combined-45000) — Sanitary Engineering, chapter 2
- [Circular sewer just full, 1.6 m³/s](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Asewer-just-full-1p6-slope-1-150) — Sanitary Engineering, chapter 3
- [Minimum sewer diameter, 80000 population](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Asewer-min-diameter-80000) — Sanitary Engineering, chapter 3
- [Combined circular sewer, 35 ha](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Acombined-sewer-35ha) — Sanitary Engineering, chapter 3
- [Circular combined sewer, 60 ha](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Acombined-sewer-60ha) — Sanitary Engineering, chapter 3
- [Separate sewer for 0.5 m³/s, 0.7 depth](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Aseparate-sewer-0p5-slope-1-in-1000) — Sanitary Engineering, chapter 3