---
title: "HR trickling filter, 2.5 MLD; change if standard"
subject: "Sanitary Engineering"
chapter: 7
key: "semester_6/sanitary_engineering:trickling-hr-2p5mld-std-compare"
source: https://www.bctengineer.com/q/semester_6/sanitary_engineering/trickling-hr-2p5mld-std-compare
site: BCT Engineering
---

# HR trickling filter, 2.5 MLD; change if standard

Sanitary Engineering · Chapter 7: Wastewater Treatment

- Asked in: 2076 Bhadra, 8 marks
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_6/sanitary_engineering/trickling-hr-2p5mld-std-compare
- Whole chapter: https://www.bctengineer.com/md/semester_6/sanitary_engineering/chapter-7

## Question

Determine the dimensions of a high rate trickling filter for the following data: (i) Sewage flow = 2.5 MLD; (ii) Recirculation ratio = 1.5; (iii) BOD of raw sewage = 300 mg/l; (iv) BOD removal in primary settling tank = 30%; (v) Final effluent BOD desired = 35 mg/l. By what % the diameter of the filter will have to be modified if it is to be designed as a standard rate trickling filter for above requirements?

## Short answer

High-rate filter volume 1363.8 m³, depth 2.0 m, diameter 29.5 m. If designed as standard-rate, diameter must be increased by 37.5% (to 40.5 m).

## Answer

#### Data and approach

High-rate filter design uses the **NRC (National Research Council) equation**; $W$ is in kg/day of BOD applied to the filter, $V$ in m³:

$$
E = \frac{100}{1+0.4432\sqrt{\dfrac{W}{VF}}},\qquad F=\frac{1+R}{(1+0.1R)^2}
$$

#### Step 1: BOD applied to the filter and required efficiency

$$
\begin{aligned}
Q &= 2500\ \text{m}^3/\text{day}\\
\text{BOD after primary} &= 300\times(1-0.3) = 210.0\ \text{mg/l}\\
W &= Q\times BOD = 2500\times 210.0\times 10^{-3} = 525.0\ \text{kg/day}\\
E &= \frac{210.0-35}{210.0}\times 100 = 83.33\%
\end{aligned}
$$

#### Step 2: Recirculation factor

$$
F = \frac{1+1.5}{(1+0.1\times 1.5)^2} = 1.890
$$

#### Step 3: Volume

$$
83.33 = \frac{100}{1+0.4432\sqrt{W/(VF)}}\Rightarrow s=\sqrt{\frac{W}{VF}} = 0.4513 \Rightarrow VF = \frac{525.0}{0.4513^2} = 2578.1
$$

$$
V = \frac{VF}{F} = \frac{2578.1}{1.890} = 1363.8\ \text{m}^3
$$

#### Step 4: Diameter

Adopt depth $d = 2.0$ m (high-rate filters are 1.8-3 m deep).

$$
A = \frac{V}{d} = 681.9\ \text{m}^2,\qquad D = \sqrt{\frac{4A}{\pi}} = 29.47\ \text{m (adopt 29.5 m)}
$$

#### Step 5: Checks

$$
\begin{aligned}
\text{Organic loading} &= \frac{W}{V} = 0.38\ \text{kg/m}^3\text{/day}\ (\text{high rate: 0.32-1.0, OK})\\
\text{Hydraulic loading} &= \frac{Q(1+R)}{A} = 9.2\ \text{m}^3/\text{m}^2\text{/day}\ (\text{high rate: 10-40; just below, acceptable})
\end{aligned}
$$

**Answer: single-stage high-rate filter of volume about 1363.8 m³, depth 2.0 m, diameter 29.5 m.**

#### Change in diameter if designed as a standard-rate filter

A standard-rate filter has no recirculation ($R=0$, $F=1$). The same efficiency $E=83.33\%$ (same $s=0.4513$) then needs

$$
V_{std}=\frac{W}{s^2}=\frac{525.0}{0.2036}=2578.1\ \text{m}^3
$$

With the same depth of 2.0 m, $D_{std}=\sqrt{4V_{std}/(\pi\times2)}=40.5$ m, compared with $D=29.5$ m for the high-rate filter.

$$
\text{Change in diameter}=\frac{40.5-29.5}{29.5}\times100=37.5\%\ (\text{since } D\propto\sqrt{V}\propto\sqrt{F}=\sqrt{1.890})
$$

**The diameter must be increased by about 37.5%** if the filter is built as a standard-rate unit.

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. With raw BOD 300 mg/l, 30% PST removal and final BOD 35 mg/l, what filter efficiency is required?
   A. 88.3%
   B. 70%
   C. 83.33%
   D. 66.7%
   Answer: C. Settled BOD = 210 mg/l; E = (210-35)/210 = 83.33%. (Key point: Efficiency required)

2. For R = 1.5 what is F, and what does it do to the required volume?
   A. F = 1.890; the volume from the NRC equation is VF/F, so recirculation reduces the volume
   B. F = 2.5; volume increases by 2.5 times
   C. F = 1.890; volume = VF x F
   D. F = 1.5; volume is unaffected
   Answer: A. Recirculation raises F, so for the same VF the required V = VF/F is smaller. (Key point: Recirculation factor)

3. How is the standard-rate filter treated for the same efficiency?
   A. Keep R = 1.5 but halve the depth
   B. Take R = 0 so F = 1; the volume then equals VF = 2578.1 m3
   C. Use R = 1 so F = 1
   D. Use the same volume 1363.8 m3 with a deeper tank
   Answer: B. A standard-rate filter has no recirculation, so F = 1 and V_std = W/s^2 = 2578.1 m3. (Key point: Standard-rate equivalent)

4. Since D is proportional to sqrt(V) at equal depth, by what percentage must the diameter change for a standard-rate filter?
   A. Decrease by 37.5%
   B. Increase by 89%
   C. Increase by 11%
   D. Increase by about 37.5% (sqrt(1.890) - 1)
   Answer: D. V_std/V = F = 1.890, so D_std/D = sqrt(1.890) = 1.375, i.e. 37.5% larger (40.5 m vs 29.5 m). (Key point: Change in diameter)

## Related in Sanitary Engineering

- [HR trickling filter, BOD 280 mg/l](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Atrickling-hr-5mld-280) — Sanitary Engineering, chapter 7
- [Standard rate trickling filter, 3 MLD, 300 mg/l](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Atrickling-standard-3mld-300) — Sanitary Engineering, chapter 7, asked 3×
- [HR trickling filter, 5 MLD, RR 1.5](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Atrickling-hr-5mld-rr1p5) — Sanitary Engineering, chapter 7, asked 2×
- [Standard rate trickling filter, 4 MLD, NRC](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Atrickling-standard-4mld-180-nrc) — Sanitary Engineering, chapter 7
- [HR trickling filter, 5 MLD, RR 1.3](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Atrickling-single-stage-5mld-rr1p3) — Sanitary Engineering, chapter 7
- [Recirculation ratio, filter volume 510 m³](https://www.bctengineer.com/question.md?key=semester_6%2Fsanitary_engineering%3Atrickling-recirculation-ratio-510m3) — Sanitary Engineering, chapter 7
