---
title: "Isolated footing 350x350, 1500 kN"
subject: "Design of RCC Structure"
chapter: 11
key: "semester_7/design_of_rcc_structure:isolated-footing-350x350-1500-kn"
source: https://www.bctengineer.com/q/semester_7/design_of_rcc_structure/isolated-footing-350x350-1500-kn
site: BCT Engineering
---

# Isolated footing 350x350, 1500 kN

Design of RCC Structure · Chapter 11: Design of Footings

- Asked in: 2075 Chaitra, 10 marks
- Video: [Design of a Square Footing](https://www.youtube.com/watch?v=jYCc0QFKwR4) — Stan Academy
- Answer checked by Claude Opus 5.5 (high effort) on 2026-10-14
- Page: https://www.bctengineer.com/q/semester_7/design_of_rcc_structure/isolated-footing-350x350-1500-kn
- Whole chapter: https://www.bctengineer.com/md/semester_7/design_of_rcc_structure/chapter-11

## Question

Design a R.C.C isolated footing to carry an axial load of 1500 kN. The column is 350 mm x 350 mm in size with 20 mm diameter, 8 Nos longitudinal bars. The bearing capacity of soil is 175 kN/m$^2$. Use M20 grade concrete and Fe415 grade steel. Assume missing datas.

## Short answer

Area = 1.1*1500/175 = 9.43 m², provide 3.1 m square. Factored pressure 234.1 kN/m²; depth D=650 mm (d=590 mm). Reinforcement 16 mm @ 185 c/c both ways; shear safe. Bearing stress 18.37 MPa > 9 MPa, excess 1148 kN requires dowels; column bars plus 4 extra 16 mm bars provide 3317 mm².

## Answer

#### Data and assumptions
- Column 350 mm × 350 mm (long side $a=350$ mm along the footing length); footing concrete M20, steel Fe415; column concrete M20; column bars 8-20 mm.
- Service load $P = 1500$ kN.
- Allowable (safe) bearing capacity of soil = 175 kN/m².
- Axial load taken as service load; column concrete M20 assumed.
- Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth $d = D - 60$ mm (cover + half bar). Load factor 1.5.

#### Size of footing
Weight of footing and backfill is taken as 10% of the column load.
$$
A_{req} = \frac{1.1\,P}{q_a} = \frac{1.1 \times 1500.0}{175} = 9.43\ \text{m}^2
$$
Provide a square footing $L \times B = 3.1 \times 3.1$ m, area = 9.61 m² $\ge$ 9.43 m².

#### Factored soil pressure
$P_u = 1.5 \times 1500.0 = 2250.0$ kN.
$p_u = \dfrac{P_u}{BL} = \dfrac{2250.0}{3.1 \times 3.1} = 234.1$ kN/m².

#### Bending moments and reinforcement
Cantilever projections from the column face: along $L$: $(3100 - 350)/2 = 1375$ mm; along $B$: $(3100 - 350)/2 = 1375$ mm.
$M_u = p_u \times (\text{width}) \times \dfrac{(\text{projection})^2}{2}$: $M_{u,L} = 686.1$ kN·m, $M_{u,B} = 686.1$ kN·m.
Required depth for flexure: $M_{u,lim} = 0.138 f_{ck} b d^2$ is far larger than the moment for $d = 590$ mm, so the depth is governed by shear (one-way or punching). Trial **$D = 650$ mm, $d = 590$ mm**, found by the shear checks below.

$A_{st} = \dfrac{0.5 f_{ck}}{f_y}\left[1 - \sqrt{1 - \dfrac{4.6 M_u}{f_{ck} b d^2}}\right] b d$; minimum steel = 0.12% of $bD$.
| Direction | $M_u$ (kN·m) | $A_{st}$ req (mm²) | Provide | $A_{st}$ prov (mm²) |
|---|---|---|---|---|
| Along $L$ (width $B$) | 686.1 | 3350 | 16 mm @ 185 c/c | 3369 |
| Along $B$ (width $L$) | 686.1 | 3350 | 16 mm @ 185 c/c | 3369 |

#### Check for one-way shear (at distance $d$ from the column face)
- Along $L$ side: $V_u = 569.8$ kN, $\tau_v = \dfrac{V_u}{B d} = 0.312$ MPa; $p_t = 0.184\%$, $\tau_c = 0.315$ MPa (IS 456 Table 19, SP 16 formula). $\tau_v < \tau_c$, safe.
- Along $B$ side: $V_u = 569.8$ kN, $\tau_v = 0.312$ MPa; $p_t = 0.184\%$, $\tau_c = 0.315$ MPa. Safe.

#### Check for two-way (punching) shear (at $d/2$ from the column face)
- Perimeter $b_o = 2[(a + d) + (c + d)] = 2[(350+590) + (350+590)] = 3760$ mm
- $V_u = P_u - p_u (a+d)(c+d) = 2250.0 - 234.1 \times 0.940 \times 0.940 = 2043.1$ kN (average pressure; the effect of moment transfer is neglected).
- $\tau_v = \dfrac{V_u}{b_o d} = 0.921$ MPa; $k_s = 0.5 + \beta_c = 1.00$, $\tau_c' = k_s \times 0.25\sqrt{f_{ck}} = 1.118$ MPa. $\tau_v < \tau_c'$, **safe**.

#### Development length
$L_d = \dfrac{0.87 f_y \phi}{4\tau_{bd}}$, $\tau_{bd} = 1.92$ MPa (M20, deformed bars): 16 mm bars (both directions) → $L_d = 752$ mm.
Available length from column face (less 50 mm end cover): 1325 mm along $L$, 1325 mm along $B$. **Satisfied** in both directions.

#### Bearing stress and transfer of load from column
Column area $A_2 = 350\times350 = 0.122$ m². Bearing stress $= P_u/A_2 = 18.37$ MPa.
Permissible bearing stress: column concrete $0.45 f_{ck} = 9.00$ MPa; footing concrete $0.45 f_{ck}\sqrt{A_1/A_2}$ with $\sqrt{A_1/A_2} \le 2$ gives up to 18.00 MPa. The lesser, 9.00 MPa, governs.
Capacity of bearing = 1102 kN $<$ $P_u = 2250$ kN, so the excess 1148 kN must be carried by dowels: $A_{s,dow} = \dfrac{1147500}{0.87 f_y} = 3178$ mm²; the column bars (8-20 mm, 2513 mm²) are continued into the footing as dowels, and 4 extra bars of 16 mm (804 mm²) are added, giving 3317 mm² $\ge$ 3178 mm².
Dowel length in compression $L_{dc} = \dfrac{0.87 f_y\phi}{4 \times 1.25\,\tau_{bd}} = 752$ mm (and the same lap with the column bars). Available depth in footing = 650 - 50 - 32 = 568 mm $< L_{dc}$; dowels are bent at the bottom with 90° bends.

#### Detailing
```text
PLAN                      ELEVATION
+------------------+      col
| #  #  #  #  #  # |      | |
| #  +------+  #  # |     _|_|__
| #  | col  |  #  # |    |_____|  <- D = 650 mm
| #  +------+  #  # |    bars both ways
| #  #  #  #  #  # |
+------------------+
 L = 3.1 m, B = 3.1 m
```
- Bottom mesh: 16 mm @ 185 c/c along $L$ (lower layer), 16 mm @ 185 c/c along $B$ (upper layer), 50 mm clear cover; dowels 8-20 mm.

**Answer:** Footing 3.1 m × 3.1 m × 650 mm thick; 16 mm @ 185 c/c along the length and 16 mm @ 185 c/c along the width.

## Check yourself

The answer's key points as multiple-choice questions, with the correct option and why.

1. How is the plan area found for a 1500 kN service load on soil of 175 kN/m^2?
   A. A = P/q = 8.57 m^2
   B. A = 1.1P/q_a = 9.43 m^2, with 10% added for footing and backfill weight
   C. A = 1.5P/q_a
   D. A = P/(1.1 q_a)
   Answer: B. Adding 10% of P for self-weight and backfill gives 1.1 x 1500/175 = 9.43 m^2, so 3.1 x 3.1 m (9.61 m^2) is provided. (Key point: Size of footing)

2. What is the punching shear result for d = 590 mm?
   A. tau_v = 0.921 MPa < allowable k_s x 0.25 sqrt(f_ck) = 1.118 MPa, safe
   B. tau_v = 0.921 MPa exceeds 0.25 sqrt(f_ck), unsafe
   C. tau_v is compared with tau_c from Table 19
   D. Punching shear is not needed for square columns
   Answer: A. Two-way shear is checked at d/2 from the column face against k_s x 0.25 sqrt(f_ck) = 1.118 MPa; 0.921 is less, so safe. (Key point: Punching shear)

3. Bearing capacity is 1102 kN, P_u = 2250 kN. What follows?
   A. Nothing, column bars are enough
   B. The excess 1148 kN needs A_s = 1147500/(0.87 f_y) = 3178 mm^2, more than the column bars 2513 mm^2, so extra dowels are required
   C. The footing must be made 2.1 m deep
   D. Bearing stress is raised to 18 MPa
   Answer: B. Dowels must carry the load beyond bearing capacity; 3178 mm^2 exceeds the 8-20 mm bars (2513 mm^2), so extra dowel bars are added. (Key point: Dowels carry excess load)

## Related in Design of RCC Structure

- [Footing 350x350, 8-16 mm bars, reversible moment](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Afooting-350x350-8-16-mm-bars) — Design of RCC Structure, chapter 11
- [Footing, 1250 kN column load, depth 1.8 m](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Afooting-1250-kn-column-load-depth) — Design of RCC Structure, chapter 11
- [Footing for 400x400 column, 1500 kN](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Afooting-for-400x400-column-1500-kn) — Design of RCC Structure, chapter 11
- [Isolated footing 450x450, service moment 110 kNm](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Aisolated-footing-450x450-service-moment-110) — Design of RCC Structure, chapter 11, asked 2×
- [Footing, 450x500 column, 6#20, uniaxial moment](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Afooting-450x500-column-6-20-uniaxial) — Design of RCC Structure, chapter 11
- [Isolated footing 400x400, service moment 120 kNm](https://www.bctengineer.com/question.md?key=semester_7%2Fdesign_of_rcc_structure%3Aisolated-footing-400x400-service-moment-120) — Design of RCC Structure, chapter 11, asked 2×

## Related in other subjects

- [Brick column design for 80 kN axial load](https://www.bctengineer.com/question.md?key=semester_5%2Fconcrete_technology_and_masonry_structure%3Abrick-column-80kn-roof) — Concrete Technology and Masonry Structure, chapter 8
- [Box deodar column, 60 mm planks, 350 kN](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Atimber-box-column-deodar-5m-350kn) — Design of Steel and Timber Structure, chapter 11
- [Footing size from plate load test curve](https://www.bctengineer.com/question.md?key=semester_5%2Ffoundation_engineering%3Aplate-load-footing-size-3200kn) — Foundation Engineering, chapter 6
- [Built-up column, two channels toe-to-toe, 1500 kN](https://www.bctengineer.com/question.md?key=semester_6%2Fdesign_of_steel_and_timber_structure%3Abuiltup-1500kn-10m-toe-to-toe) — Design of Steel and Timber Structure, chapter 6
