Relative stability from Bode plot
Short answer
Relative stability is measured by gain margin (GM) and phase margin (PM) from the open-loop Bode plot. GM = −20 log|GH| at phase crossover (∠GH=−180°); PM = 180° + ∠GH at gain crossover (0 dB). Positive margins indicate stability; typical design values are GM ≥ 6 dB and PM 30°–60°. PM ≈ 100ζ for damping estimation.
Discuss how Bode plot is used for determining relative stability.
Relative stability tells how far a stable system is from becoming unstable. On a Bode plot it is measured by the gain margin (GM) and phase margin (PM), read directly from the magnitude and phase curves of the open-loop transfer function .
Procedure
- Draw the magnitude plot (dB) and phase plot of on the same frequency axis.
- Gain crossover frequency : where the magnitude curve crosses 0 dB.
- Phase crossover frequency : where the phase curve crosses .
- Gain margin:
i.e. the distance of the magnitude curve below 0 dB at . 5. Phase margin:
i.e. the distance of the phase curve above at .
dB |\
0 |-\----------+-------- w
| \ wgc | ^ GM
| \ | v
deg | |
-180 |----+-------x-------- w
| ^ PM wpc
Interpretation (minimum-phase systems)
| Condition | Closed-loop system |
|---|---|
| GM > 0 dB and PM > 0°, i.e. | Stable |
| GM = 0 dB, PM = 0°, | Marginally stable (sustained oscillation) |
| GM < 0 dB or PM < 0°, i.e. | Unstable |
- Larger margins mean more relative stability. GM tells by how much the gain can be increased before instability; PM tells how much extra phase lag (e.g. a time delay) can be added.
- Good design values: GM ≥ 6 dB and PM of about 30°–60°.
- PM is linked to damping: approximately for PM below about 70°. Small PM means a large overshoot.
Example: for a system with rad/s, phase there, and magnitude dB at : PM = 30°, GM = 10 dB, so the system is stable with reasonable margin.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Determining transfer function from Bode plot · Control Systems, chapter 6 · asked 2×
- Relative stability using R-H criterion · Control Systems, chapter 4 · asked 2×
- Bode plot of 512(s+3)/[s(s²+16s+256)] · Control Systems, chapter 6 · asked 4×
- Bode plot of 60/[s(s+2)(s+6)] with gain margin · Control Systems, chapter 6 · asked 4×
- Bode plot of 50(s+10)/[(s+1)(s+100)] · Control Systems, chapter 6 · asked 3×
- Bode plot of 40(s+2)/[(2+s+25s²)(1+2s)s] · Control Systems, chapter 6 · asked 3×
- Bode plot: 10(S+10)/(S(S²+5S+4)(S+40)) · Electrical Circuit Theory, chapter 5 · asked 4×
- Bode plot: 64(S+2)/(S(S²+0.5S)(S²+3.2S+64)) · Electrical Circuit Theory, chapter 5 · asked 4×
- Bode plot: 200(S+1)/(S(S+5)(S²+2S+100)) · Electrical Circuit Theory, chapter 5 · asked 4×
- Bode plot: 20(S+1)/((S²+4S+2)(S²+5S)) · Electrical Circuit Theory, chapter 5 · asked 4×