Measures to track the reference input
Short answer
Use a closed-loop system with integral action (PI or PID controller) to raise the system type. An integrator makes the position error constant infinite for step inputs, eliminating the steady-state error permanently because the integral term accumulates any error and forces the output to match the reference.
There exists a permanent mismatch to track the reference by the actual system. Suggest a way out to follow your system as per reference and justify.
A permanent mismatch between the reference and the output is a steady-state error . It can be removed by using a closed-loop system with integral action (PI or PID controller), i.e. by raising the type number of the loop.
Justification
For unity feedback, and
For a unit step, , where the position error constant is .
- Type-0 system, e.g. : , so . The mismatch is permanent.
- Raising reduces the error (e.g. gives 1%) but never makes it zero, and high gain can make higher-order systems oscillatory or unstable.
- Add an integrator (PI controller ): the loop becomes type 1 and the position constant , so
The integrator keeps changing its output as long as any error exists, so the output is forced to follow the reference exactly.
Other measures
- If the system is open loop, convert it to closed loop with a sensor so that the error is measured and corrected.
- For ramp references, use a type-2 loop (double integration) or a lag compensator to raise .
- Calibrate the sensor and feedback element: an error in appears directly in the output, since .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Block diagram reduction with G4 on input and H1–H2 · Control Systems, chapter 3 · asked 2×
- How feedback rejects disturbance input · Control Systems, chapter 1
- Block diagram reduction with H4 input feedforward · Control Systems, chapter 3
- Y/R by block reduction with G4 from input · Control Systems, chapter 3
- Derivative feedback for ramp input · Control Systems, chapter 7
- Tracking, disturbance rejection and pole sensitivity · Control Systems, chapter 3
- In-plane, out-of-plane failure and remedial measures · Concrete Technology and Masonry Structure, chapter 9
- Initial mismatch and Jacobian, 2-bus system · Power System Analysis II, chapter 2
- Principles of laying out water supply system · Building Technology, chapter 12
- Report on electricity demand-supply mismatch · Communication English, chapter 9