- 2076 Chaitra · 1+4 marks
Hazard types and hazard cover in K-maps
Short answer
A hazard is a momentary glitch caused by unequal propagation delays. Static-1 hazard: output should stay 1 but briefly goes to 0 in SOP circuits; static-0: stays 0 but glitches to 1 in POS; dynamic: multiple transitions. Hazard cover: add a redundant prime implicant covering adjacent 1s not in the same group (e.g., add BC to F=AB+A'C) to eliminate static hazards.
What is hazard? Explain types of hazards with hazard cover techniques used in K-map simplification.
A hazard is an unwanted momentary pulse (glitch) at the output of a combinational circuit, caused by unequal propagation delays along different paths when an input changes. The steady-state output is correct, but the transient is wrong; in sequential systems such glitches can trigger flip-flops falsely.
Types of hazards
| Type | Expected output | Actual output | Usually found in |
|---|---|---|---|
| Static-1 | stays 1 | SOP (AND-OR) circuits | |
| Static-0 | stays 0 | POS (OR-AND) circuits | |
| Dynamic | one change, | multi-level circuits |
- Static hazard: the output should not change, but it briefly changes and returns.
- Dynamic hazard: the output should change once but changes several times, because the changing input reaches the output by three or more paths of different delay.
Hazard cover in K-maps (example)
BC
A 00 01 11 10
+---+---+---+---+
0 | 0 | 1 | 1 | 0 | A'C = cells 1, 3
+---+---+---+---+
1 | 0 | 0 | 1 | 1 | AB = cells 7, 6
+---+---+---+---+
Cells 3 (011) and 7 (111) are adjacent 1s but lie in different groups. With , F should stay 1 while A changes. When A goes , the term falls at once but rises only after the inverter delay, so F momentarily becomes 0: a static-1 hazard.
Hazard cover technique: add a redundant group that covers every pair of adjacent 1s not already in a common group. Here the extra group is cells 3 and 7, i.e. the consensus term :
While A changes with , keeps F at 1, so the glitch disappears. The function is unchanged (consensus theorem: ), only the circuit gains one gate.
Rules
- For SOP circuits: every two adjacent 1-cells must be covered by at least one common prime implicant (removes static-1 hazards).
- For POS circuits: every two adjacent 0-cells must be covered by a common sum term (removes static-0 hazards).
- A two-level circuit built with full hazard cover is also free of dynamic hazards; dynamic hazards are avoided by not using multi-level paths for the same variable.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Hazards and device to map BTS radiation zones · RF and Microwave Engineering, chapter 7
- Strength of double cover butt joint, M20 · Design of Steel and Timber Structure, chapter 4
- Topographical and geological maps for materials · Engineering Geology II, chapter 7 · asked 7×
- Emission hazards and health impact · Energy Environment and Society, chapter 4 · asked 2×