- 2072 Chaitra · 6 marks
Lateral load effect on wall with and without opening
Short answer
A solid wall resists lateral load as a monolith, failing with a single diagonal crack. Openings break the wall into piers and spandrels, drastically reducing stiffness and causing stress concentrations and diagonal cracks from corners; short piers fail in shear, slender ones rock. IS 4326 limits opening lengths and requires bands.
Explain the effect of lateral loads on masonry wall with and without opening in wall.
Wall without opening
A solid wall acts as a monolithic shear wall (in-plane) or plate (out-of-plane). The lateral force is carried by one wide section, so the stiffness and strength are high. Typical failure: a single large diagonal crack, or sliding or rocking at the base. The capacity is calculated on the full length : .
Wall with openings
Doors and windows break the wall into piers (vertical strips between openings) and spandrels (horizontal strips above and below the openings).
- Stiffness and strength fall sharply; the lateral force is shared among the piers in proportion to their stiffness (stiffness and falls with for slender piers).
- Stress concentrations at the corners of openings cause diagonal cracks radiating from the corners.
- Short, stocky piers fail in shear; slender piers fail by rocking (flexure); spandrels crack in shear and flexure.
- Out-of-plane: the section is weaker at the opening, cracks run from the corners of the opening to the edge, and the wall can fail at lintel or sill level.
No opening With opening
+---------+ +----+-----+----+
| \ / | | pier|open| pier|
| \ / | -> | / | | \ |
+---------+ +----+-----+----+
single X-crack cracks from the corners
Hence IS 4326 limits the total length of openings (not more than 50 percent of the wall length for one storey, 42 percent for two storeys and 33 percent for three storeys), sets a minimum distance of an opening from an inside corner and a minimum width of the pier between openings (the values depend on the building category), and requires lintel bands and sill bands, or reinforcement around openings.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Design process for masonry wall under lateral loads · Concrete Technology and Masonry Structure, chapter 9
- Elements resisting lateral loads in masonry · Concrete Technology and Masonry Structure, chapter 9 · asked 6×
- Typical damage in masonry under lateral loads · Concrete Technology and Masonry Structure, chapter 9 · asked 2×
- Common deficiency and failure under gravity, lateral loads · Concrete Technology and Masonry Structure, chapter 9
- Lateral load elements; stepwise [cut off] · Concrete Technology and Masonry Structure, chapter 9
- Diagonal shear test of masonry wall · Concrete Technology and Masonry Structure, chapter 10 · asked 6×
- Distribution of lateral force among masonry walls · Design of Timber and Masonry Structures, chapter 6
- Wall with openings: pier loads and check · Design of Timber and Masonry Structures, chapter 5
- Out-of-plane bending of a masonry wall · Design of Timber and Masonry Structures, chapter 6
- Check of a solid brick wall under gravity load · Design of Timber and Masonry Structures, chapter 5
All Concrete Technology and Masonry Structure chapter 9 questions →