Seismic behaviour of unreinforced and reinforced masonry

Short answer

URM buildings are heavy and brittle, with low tensile strength, leading to brittle shear or out-of-plane failure and low ductility (R≈1.5). Reinforced masonry uses steel bars to carry tension, providing box action, ductile flexural failure, and higher ductility (R≈3).

Explain the seismic behaviour of unreinforced masonry (URM) buildings. How does reinforced masonry perform better? Differentiate between them.

Seismic behaviour of unreinforced masonry

  • Heavy and brittle: the mass attracts large inertia force (F=maF = ma) while the masonry has low tensile and shear strength, so cracks form early.
  • Load path: seismic forces from the roof pass through the floor diaphragm to the walls parallel to the force (shear walls); walls normal to the shaking bend out of plane.
  • Typical damage: diagonal cracks in piers, corner separation, out-of-plane collapse of walls and gables, and delamination of wall leaves.
  • Weak connections between walls and floors, and no continuous ties, lead to collapse of walls one by one rather than box action.
  • URM has very small ductility; the response reduction factor RR used in design is small (about 1.5).

Seismic behaviour of reinforced masonry

  • Vertical bars (in grouted cores) and horizontal bars (in bond beams) carry the tension caused by bending and shear, giving good strength and ductility.
  • Walls act as a box, with continuous bond beams tying walls and floors, and out-of-plane strength is higher.
  • Cracks are fine and distributed; energy is dissipated by yielding of steel, and the wall retains vertical load capacity after cracking.
  • Because of its ductility, a larger RR (about 3) is allowed, so the design force is smaller.

Comparison

PointUnreinforced masonryReinforced masonry
Tensile strengthVery lowProvided by steel
FailureBrittle shear / out-of-planeDuctile flexure (if designed)
Energy dissipationPoorGood
DuctilityAbout 1–1.5Moderate to high
Design RRLowHigher
Post-cracking capacityDrops quicklyRetained
CostLowerHigher (steel, grout, labour)
Height permittedLow (1–3 storeys)More storeys

URM can be made safer by confining with RC bands, tie columns and vertical bars at corners.

✓ Answer checked by Claude Sonnet 5.5