True/False: armature reaction and ampere conductors
Short answer
TRUE. Armature mmf per pole is directly proportional to ampere conductors per metre, so a larger ac causes stronger armature reaction and flux distortion.
State and justify whether the following statement is TRUE or FALSE: Armature reaction in DC machine is depended on large value of ampere conductor.
TRUE.
The armature mmf per pole is
So, for a given diameter and number of poles, armature mmf is directly proportional to the specific electric loading . A large produces strong armature reaction: more cross-magnetisation, more distortion of the gap flux, more demagnetising effect at saturation, and poorer commutation. A larger field mmf (or compensating winding) is then needed.
Example: with A/m, m and , A per pole; doubling doubles this armature mmf. Hence designers limit , or add interpoles and compensating windings in heavily loaded machines.
✓ Answer checked by Claude Sonnet 5.5