Skip to main content

Double ring infiltrometer, phi-index versus W-index

Short answer

A double-ring infiltrometer uses an outer buffer ring to ensure vertical infiltration; capacity is the steady rate from inner-ring water added over time. The φ-index is a constant loss rate yielding rainfall excess equal to runoff, while the W-index subtracts initial losses and applies only when intensity exceeds capacity.

Explain with neat sketch to determine the infiltration capacity of soil by using double ring infiltrometer. How do you differentiate ϕ\phi index from ω\omega-index?

Double ring infiltrometer

It consists of two concentric metal rings: an inner ring (about 30 cm diameter) and an outer ring (about 60 cm diameter), each 25 to 30 cm tall.

   ___________________________
  |   outer   |inner|  outer  |
  |   ring    |ring |  ring   |
  |  ~~~~~~~~~|~~~~~|~~~~~~~~ | <- same water level
  |           |     |         |
 =|===========|=====|=========|= ground
              |  |  |
              v  v  v  vertical flow

Procedure:

  1. Drive both rings about 15 cm into the ground, keeping them level and concentric.
  2. Fill both rings with water to the same depth (about 5 cm) and keep this depth constant by adding water.
  3. The water in the outer ring prevents lateral spreading from the inner ring.
  4. Record the volume added to the inner ring at fixed intervals (e.g. 5, 10, 15, 30, 60 min) until the rate becomes steady.
  5. Infiltration capacity f=ΔVAinner Δtf = \dfrac{\Delta V}{A_{inner}\,\Delta t} is plotted against time; the final steady value is fcf_c.

Difference between ϕ\phi-index and W-index (ω\omega-index)

Pointϕ\phi-indexW-index
DefinitionConstant infiltration rate above which the rainfall volume equals the runoff volumeAverage infiltration rate during the time that rain intensity exceeds infiltration capacity
Formulaϕ=(P−R)/te\phi = (P-R)/t_e, where tet_e is the duration of rainfall excessW=(P−R−Ia)/trW = (P-R-I_a)/t_r, where IaI_a is the initial loss (interception and depression storage) and trt_r is the time when rain intensity exceeds infiltration capacity
Initial lossIncluded in the lossSubtracted separately (interception and depression storage are removed first)
Period usedPeriods with rain below ϕ\phi are not given any excessOnly the time when intensity exceeds capacity is counted
ValueUsually slightly largerUsually slightly smaller
AccuracyRoughBetter, as it accounts for storage

✓ Answer checked by Claude Sonnet 5.5

All Engineering Hydrology chapter 3 questions →