Skip to main content

Gumbel design flood, factor of safety 1.3, 45-year life

Short answer

With 85% reliability in 45 years, T = 277 years. y_T = 5.624, K = 4.666, peak discharge x_T = 26717 m³/s. With safety factor 1.3: design discharge = 34732 m³/s, safety margin = 8015 m³/s.

Analysis of the annual flood peak data of a certain river covering the period of 25 years has the mean of 8520 and standard deviation of 3900 m3^3/s. The proposed water control project near this site has an expected life of 45 years. The policy decision for project provides the reliability of 85%.

(i) Using Gumbel's method recommend peak discharge. Take yn=0.5309y_n = 0.5309 and Sn=1.0915S_n = 1.0915

(ii) Calculate the design discharge if factor of safety is 1.3 and also the corresponding safety margin.

(i) Peak discharge by Gumbel's method

Given: N=25N = 25 years, xˉ=8520 m3/s\bar{x} = 8520\ \text{m}^3/\text{s}, σ=3900 m3/s\sigma = 3900\ \text{m}^3/\text{s}, yn=0.5309y_n = 0.5309, Sn=1.0915S_n = 1.0915, design life n=45n = 45 years, reliability =85%= 85\%.

Return period. Reliability =(1−1/T)n=0.85= (1 - 1/T)^n = 0.85, so risk Rˉ=1−0.85=0.15\bar{R} = 1 - 0.85 = 0.15.

1−1T=(0.85)1/45=0.996395T=277.4 years\begin{aligned} 1 - \frac{1}{T} &= (0.85)^{1/45} = 0.996395\\ T &= 277.4\ \text{years} \end{aligned}

Reduced variate.

yT=−ln⁡[ln⁡TT−1]=−ln⁡[ln⁡277.4276.4]=5.6236y_T = -\ln\left[\ln\frac{T}{T-1}\right] = -\ln\left[\ln\frac{277.4}{276.4}\right] = 5.6236

Frequency factor.

K=yT−ynSn=5.6236−0.53091.0915=4.6658K = \frac{y_T - y_n}{S_n} = \frac{5.6236 - 0.5309}{1.0915} = 4.6658

Flood magnitude.

xT=xˉ+Kσ=8520+(4.6658)(3900)=26717 m3/sx_T = \bar{x} + K\sigma = 8520 + (4.6658)(3900) = 26717\ \text{m}^3/\text{s}

Answer (i): recommended peak discharge ≈\approx 26717 m³/s (return period about 277 years).

(ii) Design discharge with factor of safety 1.3

Qdesign=1.3×26717=34732 m3/sQ_{design} = 1.3 \times 26717 = 34732\ \text{m}^3/\text{s}

Safety margin =Qdesign−xT=34732−26717=8015 m3/s= Q_{design} - x_T = 34732 - 26717 = 8015\ \text{m}^3/\text{s} (30 % of xTx_T).

Answer (ii): design discharge = 34732 m³/s; safety margin = 8015 m³/s.

✓ Answer checked by Claude Sonnet 5.5

All Engineering Hydrology chapter 6 questions →