How stage-discharge relationship is established
Short answer
Select stable site, install gauge, measure discharges at various stages by current meter. Plot stage vs discharge, fit Q=C(G-a)^b: determine a (zero-flow stage) by trial or three-point method, log-log regression for C and b, and verify correlation.
Explain how stage discharge relationship is established.
A stage-discharge relationship (rating curve) at a gauging site is established as follows.
- Select the site with a stable, permanent control and a straight reach.
- Install a gauge (staff gauge or automatic recorder) and note the datum.
- Measure discharge at various stages, from low to flood, by the area-velocity (current meter) method, and simultaneously record the stage. A minimum of about 15 to 20 measurements covering the whole range is desirable.
- Plot the stage against discharge on arithmetic paper; draw a smooth curve through the points.
- Fit the equation :
- Find , the stage at zero discharge (by trial, or the three-point method with ).
- Plot against ; a straight line is obtained when is correct; its slope is and intercept is .
- Check the correlation and test the curve by new measurements.
- Extrapolate the curve above the highest measured stage by the log-log straight line or the conveyance (Manning) method.
- Review periodically: if the points depart from the curve (shifting control), apply shift corrections or draw a new curve.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Shifting control in stage-discharge relation · Engineering Hydrology, chapter 4
- Rating curve equation, zero-discharge stage 161.0 m · Engineering Hydrology, chapter 4
- Gauge-discharge relationship and discharge at 10.5 m · Engineering Hydrology, chapter 4
- Stage at zero discharge from rating data · Engineering Hydrology, chapter 4 · asked 2×
- Zero-discharge stage of a smooth rating curve · Engineering Hydrology, chapter 4 · asked 2×
- Stage for zero discharge with sketch · Engineering Hydrology, chapter 4
- Stage discharge curve and its application · Hydro Power, chapter 2
- Arrester coordination for 40 kA discharge · High Voltage Engineering, chapter 4 · asked 2×