A sampler has the following dimensions: inside diameter of cutting edge = 59 mm; outside diameter of cutting edge = 63 mm; inside diameter of sampling tube = 60 mm and outside diameter of sampling tube = 62 mm. Calculate (i) area ratio (ii) inside clearance (iii) outside clearance.
Given: mm (cutting edge inside), mm (cutting edge outside), mm (tube inside), mm (tube outside).
(i) Area ratio
(ii) Inside clearance
(iii) Outside clearance
Answer: , , . (The clearances are acceptable, but , so the sample would be slightly disturbed.)