Skip to main content

Define grip length, tilt and shift

Short answer

Grip length: depth below max scour level, ≥1/3 of max scour depth. Tilt: inclination of well axis from vertical, permissible 1 in 80. Shift: lateral displacement of the well centre from design position, permissible about 150 mm.

Define grip length and tilt and shift of well.

  • Grip length: the depth of a well foundation below the maximum scour level; at least one-third of the maximum scour depth. It gives the lateral stability of the well.
  • Tilt: the inclination of the axis of the well from the vertical, which occurs during sinking because of uneven dredging or obstructions; the permissible tilt is 1 in 80.
  • Shift: the lateral displacement of the centre of the well from its designed position, at the base or at the top; the permissible shift is about 150 mm.