Velocity, head loss, discharge in pipes BC, CD, BF, FD (0.1 m)

Short answer

Hardy-Cross solution gives: BC 2.809 m³/s (357.7 m/s, hf=195605 m); CD 1.809 m³/s (230.3 m/s, 162256 m); BF 2.191 m³/s (279.0 m/s, 356948 m); FD 0.192 m³/s (24.4 m/s, 913 m).

Determine the velocity, head loss and discharge in the pipes BC, CD, BF and FD. The length of pipe BC, CD, BF and FD are 100 m, 200 m, 300 m and 100 m respectively and dia of all pipes are 0.1 m and Darcy's coefficient of friction, f = 0.03.

[Figure: 5 m3^3/s enters at A and reaches B; the loop B-C-D-F; 1 m3^3/s leaves at C, 2 m3^3/s leaves at F, and 2 m3^3/s leaves from D towards E.]

The 5 m³/s entering at A reaches B and splits between the paths B–C–D and B–F–D. All pipes are only 0.1 m in diameter, so the numbers are not realistic (velocities of hundreds of m/s), but the method is the same.

Formulas

Darcy-Weisbach: hf=8fLQ2π2gD5=kQ2h_f = \dfrac{8 f L Q^2}{\pi^2 g D^5} = kQ^2, velocity v=Q/(πD2/4)v = Q/(\pi D^2/4). Hardy-Cross correction for the loop:

ΔQ=−∑kQ∣Q∣2∑k∣Q∣\Delta Q = -\frac{\sum kQ|Q|}{2\sum k|Q|}

Flow distribution

BC = xx, CD = x−1x - 1 (1 m³/s leaves at C), BF = 5−x5 - x and FD = 3−x3 - x (2 m³/s leaves at F). At D: CD + FD = 2 ✓. Trial: BC = 3, CD = 2, BF = 2, FD = 0 (a very small value 0.001 is used so that the correction can be calculated).

Constants k for each pipe (f=0.03f = 0.03)

PipeL (m)D (m)k = 8fL/(π²gD⁵)
BC1000.124788.0572
CD2000.149576.1143
BF3000.174364.1715
FD1000.124788.0572

Hardy-Cross iterations (clockwise positive; flows in m³/s)

IterationΔQBCCDBFFD
1-0.19232.80771.80772.19230.1933
2+0.00142.80911.80912.19090.1919
3+0.00002.80911.80912.19090.1919
4+0.00002.80911.80912.19090.1919

Results

PipeDischarge (m³/s)Velocity (m/s)Head loss (m)
BC2.8091357.667195604.8111
CD1.8091230.343162256.3632
BF2.1909278.953356948.4203
FD0.191924.432912.7540

Check: upper path = 357861.2 m; lower path = 357861.2 m ✓

Answer: BC = 2.809 m³/s (v = 357.7 m/s, h_f = 195605 m); CD = 1.809 m³/s (230.3 m/s, 162256 m); BF = 2.191 m³/s (279.0 m/s, 356948 m); FD = 0.192 m³/s (24.4 m/s, 913 m). The very large velocities and head losses show that the data (5 m³/s through 100 mm pipes) is not physically practical; the pipe sizes must be increased in a real design.