- Asked 2/21
- 2075 Bhadra · 14 marks
Beam supporting RCC slab, DL 10 kN/m, IL 30 kN
Short answer
ISMB 450. Factored moment 274.8 kN·m < capacity 348.7 kN·m; shear 183.2 kN < 555 kN; deflection 8.33 mm < 20 mm. Lateral buckling is prevented by the continuous slab restraint.
A simply supported beam of span 6 m supports a reinforcement concrete slab. The compression flange of the beam is restrained due to its connection with the slab. The beam is subjected to a dead load of 10 kN/m and imposed load of 30 kN. Design the beam. Assume the beam is sufficiently stiff against bearing.
Data
- Steel Fe 410 (E250): N/mm², N/mm², N/mm², (IS 800:2007, Table 5). Limit state design.
- Effective span m.
Loads and design forces
Span m. The "30 kN" imposed load is read as 30 kN/m (a UDL, like the dead load of 10 kN/m); dead load is taken to exclude the beam's own weight. Factored load kN/m, plus factored self-weight. The beam is "sufficiently stiff against bearing", so the web buckling and bearing checks are not required.
Moment without self-weight kN·m, so cm³ (self-weight adds a little).
Trial section
Try ISMB 450 (IS 808): mm, mm, mm, mm, mm; cm⁴; cm³; cm³; mass kg/m.
Self-weight kN/m, factored kN/m. Total factored UDL kN/m.
Section classification (Table 2)
. Flange: . Web: (with mm). The section is plastic, so .
Moment capacity (cl. 8.2.1.2)
The compression flange is restrained by the RCC slab along its full length, so lateral-torsional buckling is prevented.
The smaller value governs: kN·m.
Shear capacity (cl. 8.4)
kN ; also kN, so the shear is low and the moment capacity is not reduced (cl. 9.2.1). Web shear buckling does not govern since (cl. 8.4.2.1).
Deflection (Table 6)
Deflection under unfactored service (imposed) loads, limit span/300 (floor and roof members, Table 6):
mm mm. OK.
Web bearing/buckling at supports is not checked because the question states the beam is sufficiently stiff against bearing.
Final design
Provide ISMB 450 (72.4 kg/m): kN·m kN·m, kN kN, mm mm.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Beam supporting RCC slab, DL 25, IL 20 kN/m · Design of Steel and Timber Structure, chapter 7 · asked 2×
- Beam 6 m span with 100 kN secondary beam load · Design of Steel and Timber Structure, chapter 7
- Simply supported beam 6 m, 60 kN/m · Design of Steel and Timber Structure, chapter 7
- Simply supported I-beam: stress at flange-web junction · Strength of Materials, chapter 7
- Design simply supported beam, 6 m span · Design of RCC Structure, chapter 4
- Simply supported T-beam: max bending stresses · Strength of Materials, chapter 7
- Mid-span deflection of beam, 10 kN load · Strength of Materials, chapter 7
All Design of Steel and Timber Structure chapter 7 questions →