- 2072 Magh · 5 marks
Sprinkler layout wetting pattern
Short answer
Placing 4 sprinklers 20 m apart with 10 m throw wets only 78.5% (1257 m²) of the 1600 m² plot, leaving 343 m² dry at centre and corners because circles barely touch. To improve, use a4x4 layout at10 m spacing or increase throw to ~14.2 m for full overlap, or use triangular spacing.
A farmer with his 40 m × 40 m plot plans to irrigate his field using 4 sprinklers having a throw distance as 10 m and each placed 20 m apart. Prepare a sketch of wetting pattern of these sprinklers. Write your comments on the moisture pattern and suggest measure to improve it if required.
Layout and wetting pattern
The four sprinklers are placed 20 m apart, i.e. at the centres of the four 20 m x 20 m quarters of the plot, at (10,10), (30,10), (10,30) and (30,30) m. Each wets a circle of radius 10 m.
40 m +--------------------+
| .--. .--. |
| ( S1 ) ( S2 ) |
| '--' '--' |
| .--. .--. |
| ( S3 ) ( S4 ) |
| '--' '--' |
0 +--------------------+
0 20 40 m
neighbouring circles touch at only one point;
the 4 corners and the centre are dry
Calculation
Comments
- Neighbouring circles only touch; there is no overlap, so the centre of the plot, the four corners and the spaces between the circles stay dry.
- The depth of water is highest near each sprinkler and falls to zero at the 10 m edge, so the distribution is non-uniform (poor uniformity coefficient).
- About 21% of the plot gets no water.
Improvement
- Reduce the spacing to about 50-60% of the wetted diameter (20 m), i.e. 10-12 m square spacing, so that neighbouring circles overlap. A 3 x 3 layout (13.3 m spacing, 9 sprinklers) just covers the whole plot; a 4 x 4 layout (10 m spacing, 16 sprinklers) gives good overlap and uniformity.
- Or increase the throw radius to at least m (about 14.2 m) with the same four sprinklers, so that the circles meet at the centre and corners of each quarter.
- Use a triangular layout for better uniformity, and use part-circle sprinklers along the edges so that water is not thrown outside the plot.
- Avoid operating in high wind.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Interval and amount with 40% moisture limit · Irrigation and Drainage Engineering, chapter 2
- Irrigation interval: FC 40%, PWP 20% · Irrigation and Drainage Engineering, chapter 2 · asked 4×
- Field capacity, available moisture definitions · Irrigation and Drainage Engineering, chapter 2
- Surface drainage design, 40 ha Terai field · Irrigation and Drainage Engineering, chapter 9
- Stable depth: Q 20, d 40 mm · Irrigation and Drainage Engineering, chapter 4 · asked 2×
- Vertical drop in 10 m wide canal, Q 20 · Irrigation and Drainage Engineering, chapter 7
- Bode plot: 10(S+10)/(S(S²+5S+4)(S+40)) · Electrical Circuit Theory, chapter 5 · asked 4×
- Bode plot: 40(s+1)/((2s²+10s)(s²+2s+10)) · Electrical Circuit Theory, chapter 5
- Bode plot: 20(s+1)/(s(s+5)(s²+2s+10)) · Electrical Circuit Theory, chapter 5
- Bode plot: 2s²(S+5)/((S²+22S+40)(S+10)) · Electrical Circuit Theory, chapter 5 · asked 2×
All Irrigation and Drainage Engineering chapter 1 questions →