BOD test by dilution method

Short answer

BOD measures biodegradable organic strength for treatment design and effluent standards. Dilution method: incubate diluted sample (1-5% for sewage) in 300 mL BOD bottles at 20°C for 5 days in dark. Measure initial and final DO; BOD₅ = (D₁-D₂)/P where P = sample volume/bottle volume. Ensure 2 mg/L DO depletion and 1 mg/L residual DO. Seed correction applied if needed.

Why is BOD value important for waste water? Describe the procedure for determining BOD of waste water sample in laboratory by dilution method.

Importance of BOD value

BOD tells the amount of biodegradable organic matter in wastewater, i.e. its strength and polluting power. It is needed to

  • design the treatment units and assess their performance (percentage BOD removal),
  • decide the degree of treatment before disposal into a river, from the oxygen demand on the stream,
  • check effluent against standards, and
  • know the oxygen the sample would take from receiving water (cause of fish kill and odours). A high BOD shows heavily polluted wastewater (raw sewage 200-400 mg/L; treated effluent should be below 30-50 mg/L).

Principle

A diluted sample is incubated for 5 days at 20°C in the dark in a standard bottle, and the oxygen consumed by the microorganisms in oxidising the organic matter is measured by the dissolved oxygen (DO) before and after incubation.

Apparatus and reagents

BOD bottles (300 mL, glass-stoppered), incubator at 20 ± 1°C, pipettes, DO meter or Winkler titration set. Dilution water is prepared from distilled water, with 1 mL each per litre of phosphate buffer, MgSO4MgSO_4, CaCl2CaCl_2 and FeCl3FeCl_3 solutions (nutrients for bacteria), and aerated to saturate with oxygen. Seed (settled domestic sewage) is added if the sample has no bacteria.

Procedure

  1. Select dilutions. Sewage needs far more oxygen than water can hold, so it is diluted in such a way that, after 5 days, at least 2 mg/L of DO is used up and at least 1 mg/L of DO remains. Take 1-5% for strong wastes (raw sewage).
  2. Prepare the diluted samples: pour a measured volume of sample (e.g. 5 mL) into each of the BOD bottles and fill to the neck with dilution water without trapping air bubbles. Make a blank with only dilution water.
  3. Initial DO (D1D_1): measure the DO of one set of bottles immediately (Winkler azide method or probe).
  4. Incubate the second set, with stoppers sealed by a water seal, for 5 days at 20°C in the dark (to stop algae making oxygen).
  5. Final DO (D2D_2): after 5 days measure the DO of the incubated bottles.
  6. Calculate
BOD5=D1−D2P mg/L,P=volume of samplevolume of diluted mixtureBOD_5=\frac{D_1-D_2}{P}\ \text{mg/L},\qquad P=\frac{\text{volume of sample}}{\text{volume of diluted mixture}}

For example, 5 mL of sample in a 300 mL bottle gives P=5/300=0.0167P=5/300=0.0167. With D1=9D_1=9 and D2=5D_2=5 mg/L, BOD5=4/0.0167=240BOD_5=4/0.0167=240 mg/L. For seeded samples, a seed correction is applied, and the blank is used to check the dilution water (its depletion should be below 0.2 mg/L).

The ultimate BOD can be found by BODt=L(1−10−kt)BOD_t = L(1-10^{-kt}) if kk is known.

✓ Answer checked by Claude Opus 5.5 (high effort)