Development length and need of splices

Short answer

Development length L_d = 0.87 f_y φ/(4 τ_bd) prevents pull-out. Splices are required because bars come in limited lengths, for transport, connecting construction stages, ensuring load path continuity, and using short offcuts; lap, welded and mechanical coupler splices are used.

Define development length. Why are splices required in RCC structure?

Development length

Development length LdL_d is the length of embedded bar needed to develop its design stress 0.87fy0.87f_y by bond with the concrete:

Ld=0.87fy ϕ4 τbdL_d=\frac{0.87f_y\,\phi}{4\,\tau_{bd}}

For example, for Fe415 deformed bars in M20 concrete, τbd=1.2×1.6=1.92\tau_{bd}=1.2\times1.6=1.92 N/mm2^2 and Ld=47ϕL_d=47\phi.

Why splices are required

Reinforcing bars are available only in standard lengths (usually 12 m, and often shorter in practice because of transport). Splices (joints) are therefore needed for the following reasons:

  1. Limited length of bars: members longer than the available bar length, such as long beams, tall columns and walls, need bars to be joined.
  2. Transport and handling: long bars are difficult to carry, store and fix on site.
  3. Construction stages: column bars are left projecting above each floor and lapped with the bars of the next lift (at construction joints).
  4. Continuity of load path: splices transfer the full force from one bar to the next, so the reinforcement acts as a continuous bar.
  5. Economy: short offcuts of bars can be used instead of being wasted.

Types: lap splices (most common), welded joints and mechanical couplers. Laps should be staggered, be at least LdL_d or 30ϕ30\phi (flexural tension), and should not be placed at sections of maximum stress.