Short answer

Looping occurs in strongly unstable air, coning in neutral conditions, fanning in a strong inversion, lofting when inversion is below stack, fumigation when inversion is above with unstable layer below, and trapping between two inversions. Fumigation and looping give highest ground-level concentrations.

Explain with sketches the different plume shapes (looping, coning, fanning, lofting, fumigation and trapping) observed from a chimney, stating the atmospheric condition in which each occurs.

The shape of a plume depends on the lapse rate (stability) of the atmosphere around and above the stack.

PlumeAtmospheric conditionDescription
LoopingStrongly unstable (superadiabatic), sunny day, light windLarge eddies carry the plume up and down in loops; high but intermittent ground concentration near the stack
ConingNeutral or slightly stable (ELR ≈\approx DALR), windy or cloudyCone-shaped, spreads about equally in the vertical and horizontal; reaches the ground at a longer distance
FanningStrong inversion (stable) from the ground upward, clear calm nightPlume spreads sideways only, like a flat ribbon, and travels far at stack height; low ground-level concentration unless the stack is short
LoftingInversion below stack height, unstable/neutral abovePlume spreads upward and away; good condition, no ground-level effect
FumigationInversion above the stack, unstable layer below (after sunrise breaks the night inversion)Plume is trapped below the inversion lid and mixed down to the ground; worst case, high ground concentration
TrappingInversion above and below the stack heightPlume is confined between two stable layers and cannot disperse up or down
 Looping:     stack ~\_/~\_/~\_/~>   (large up-and-down loops)
 Coning:      stack <=========>      (cone opening downwind)
 Fanning:     stack ------------->   (thin, flat ribbon)

 Lofting:     stack  ^^^^^^^^^^^>    (spreads upward only)
              ==== inversion below stack top ====

 Fumigation:  ==== inversion above stack ====
              stack vvvvvvvvvvv>     (mixed down to ground)

 Trapping:    ==== inversion above ====
              stack <=========>      (confined)
              ==== inversion below ====

Fumigation and looping are of greatest concern for ground-level pollution; the chimney height is normally chosen for the worst of these cases.