Step-down chopper variable frequency, 3 ms ON time

Short answer

With constant Ton = 3 ms and k = 0.3, period T = Ton/k = 10 ms, so Toff = T − Ton = 7 ms. Average output voltage Vo = k · Vdc = 0.3 × 200 V = 60 V.

Figure below shows a step down dc chopper. If it is operated in variable frequency mode with ON time constant at 3msec. Calculate the OFF time for a duty cycle at 30% and average value of output voltage. [Figure: Vdc = 200 V source, a series switch, and a resistive load R with output Vo]

In variable-frequency (frequency modulation) control, TonT_{on} is kept constant and the duty cycle is changed by varying the chopping period TT (hence ToffT_{off}).

Given: Vdc=200V_{dc} = 200 V, Ton=3T_{on} = 3 ms (constant), k=0.3k = 0.3, resistive load.

OFF time

k=TonT  ⇒  T=Tonk=30.3=10 msToff=T−Ton=10−3=7 ms\begin{aligned} k &= \frac{T_{on}}{T} \;\Rightarrow\; T = \frac{T_{on}}{k} = \frac{3}{0.3} = 10\ \text{ms} \\ T_{off} &= T - T_{on} = 10 - 3 = 7\ \text{ms} \end{aligned}

Chopping frequency f=1/T=100f = 1/T = 100 Hz.

Average output voltage

Vo=kVdc=TonTon+ToffVdc=0.3×200=60 VV_o = kV_{dc} = \frac{T_{on}}{T_{on}+T_{off}}V_{dc} = 0.3\times200 = 60\ \text{V}
 vo  200|___         ___
        |   |       |   |
      0 |___|_______|___|_______ t
         3ms  7ms
        |<--- T = 10 ms --->|

Answer: Toff=7T_{off} = 7 ms; average output voltage Vo=60V_o = 60 V.

Note: variable-frequency control is simple, but a wide frequency range makes filter design hard and may cause interference; for low kk the OFF time becomes very long, so the load current may become discontinuous.