Three-phase full converter at 50% of maximum output

Short answer

Using Vdm = 1.35 times 230 V = 310.61 V, half average voltage requires alpha = 60 degrees. With R = 10 ohm, Idc = 15.53 A and Irms = 17.61 A. Rectification efficiency is Pdc/Pac = 77.74 percent.

A three phase full wave converter is operated from three phase star connected, 230 V, 50 Hz supply with resistance R = 10 ohm. An average output voltage of 50% of the maximum possible output voltage is required. Determine (i) the firing angle (ii) average and rms values of load current and (iii) rectification efficiency.

A three-phase full converter (six-thyristor bridge) gives Vdc=33Vmπcos⁡αV_{dc} = \frac{3\sqrt3V_m}{\pi}\cos\alpha, where VmV_m is the peak phase voltage. With a resistive load this holds for α≤60∘\alpha \le 60^\circ (continuous conduction).

        P (+) o-----+------+------+-----+
                    |      |      |     |
                   T1     T3     T5     |
                    |      |      |     R
 a o----------------+      |      |     |
 b o-----------------------+      |     |
 c o------------------------------+     |
                    |      |      |     |
                   T4     T6     T2     |
                    |      |      |     |
        N (-) o-----+------+------+-----+
 (a joins T1-T4, b joins T3-T6, c joins T5-T2)

Assumption: 230 V is the line voltage of the star-connected supply (as in the standard textbook problem). Then

Vph=2303=132.79 V,Vm=2×132.79=187.79 VVdm=33Vmπ=33×187.79π=310.61 V (=1.35×230)\begin{aligned} V_{ph} &= \frac{230}{\sqrt3} = 132.79\ \text{V}, \quad V_m = \sqrt2 \times 132.79 = 187.79\ \text{V} \\ V_{dm} &= \frac{3\sqrt3V_m}{\pi} = \frac{3\sqrt3 \times 187.79}{\pi} = 310.61\ \text{V}\ (= 1.35 \times 230) \end{aligned}

(i) Firing angle

Vdc=0.5Vdm=155.30 Vcos⁡α=VdcVdm=0.5⇒α=60∘\begin{aligned} V_{dc} &= 0.5V_{dm} = 155.30\ \text{V} \\ \cos\alpha &= \frac{V_{dc}}{V_{dm}} = 0.5 \quad\Rightarrow\quad \alpha = 60^\circ \end{aligned}

At α=60∘\alpha = 60^\circ the R-load current is just continuous, so the continuous-conduction formulas are valid.

(ii) Average and RMS load current

Idc=VdcR=155.3010=15.53 AI_{dc} = \frac{V_{dc}}{R} = \frac{155.30}{10} = 15.53\ \text{A} Vrms=3Vm[12+334πcos⁡2α]1/2=325.27[0.5+0.4135×(−0.5)]1/2=325.27×0.5415=176.14 VIrms=176.1410=17.61 A\begin{aligned} V_{rms} &= \sqrt3V_m\left[\frac{1}{2} + \frac{3\sqrt3}{4\pi}\cos2\alpha\right]^{1/2} = 325.27\left[0.5 + 0.4135 \times (-0.5)\right]^{1/2} \\ &= 325.27 \times 0.5415 = 176.14\ \text{V} \\ I_{rms} &= \frac{176.14}{10} = 17.61\ \text{A} \end{aligned}

(iii) Rectification efficiency

Pdc=VdcIdc=155.30×15.53=2412.0 WPac=VrmsIrms=176.14×17.61=3102.6 Wη=PdcPac=2412.03102.6=77.74 %\begin{aligned} P_{dc} &= V_{dc}I_{dc} = 155.30 \times 15.53 = 2412.0\ \text{W} \\ P_{ac} &= V_{rms}I_{rms} = 176.14 \times 17.61 = 3102.6\ \text{W} \\ \eta &= \frac{P_{dc}}{P_{ac}} = \frac{2412.0}{3102.6} = 77.74\ \% \end{aligned}

Answer: α=60∘\alpha = 60^\circ; Idc=15.53I_{dc} = 15.53 A, Irms=17.61I_{rms} = 17.61 A; η=77.74\eta = 77.74 %.

(If 230 V were taken as the phase voltage, α\alpha is still 60∘60^\circ and η\eta is still 77.74%, but Idc=26.90I_{dc} = 26.90 A and Irms=30.51I_{rms} = 30.51 A.)