Skip to main content

Gas turbine 800 kW with regenerator

Short answer

Compute compressor and turbine exit temperatures using isentropic efficiencies, then regenerator exit temperature with 80% effectiveness. Heat input is cp(T3 - Tx), net work is turbine work minus compressor work. Thermal efficiency is 24.82% and net power is 482.4 kW.

A gas turbine plant of 800 kW capacity takes the air at 100 kPa and 288K with a mass flow rate of 6 kg/s. The pressure ratio of the cycle is 6 and the maximum temperature is limited to 900 K. A regenerator of 80% effectiveness is added in the plant to increase the overall efficiency. Assuming the isentropic efficiency of the compressor and turbine as 85%, determine the plant thermal efficiency and the net power developed. Take γ =1.4, Cp =1.005 kJ/kg.K.

Cycle: 1–2 compressor, 2–x regenerator (air side), x–3 combustion chamber, 3–4 turbine, 4–y regenerator (gas side) to exhaust.

Data: p1=100p_1 = 100 kPa, T1=288T_1 = 288 K, m˙=6\dot m = 6 kg/s, rp=6r_p = 6, T3=900T_3 = 900 K, ε=0.8\varepsilon = 0.8, ηc=ηt=0.85\eta_c = \eta_t = 0.85, cp=1.005c_p = 1.005 kJ/kg K, γ=1.4\gamma = 1.4, so γ−1γ=0.2857\frac{\gamma-1}{\gamma} = 0.2857 and rp0.2857=60.2857=1.6685r_p^{0.2857} = 6^{0.2857} = 1.6685.

     +----------- Regenerator ---------+
     |  x (hot air)        y (exhaust) |
 1   |2                     4          |
 -> [C] ------> [CC] -3-> [T] ---------+
      \=========shaft=====/  ==> Gen

Compressor

T2s=T1rp0.2857=288×1.6685=480.53 KT2=T1+T2s−T1ηc=288+192.530.85=514.51 KWc=cp(T2−T1)=1.005×226.51=227.64 kJ/kg\begin{aligned} T_{2s} &= T_1 r_p^{0.2857} = 288 \times 1.6685 = 480.53\ \text{K} \\ T_2 &= T_1 + \frac{T_{2s}-T_1}{\eta_c} = 288 + \frac{192.53}{0.85} = 514.51\ \text{K} \\ W_c &= c_p (T_2 - T_1) = 1.005 \times 226.51 = 227.64\ \text{kJ/kg} \end{aligned}

Turbine

T4s=T3rp0.2857=9001.6685=539.40 KT4=T3−ηt(T3−T4s)=900−0.85×360.60=593.49 KWt=cp(T3−T4)=1.005×306.51=308.04 kJ/kg\begin{aligned} T_{4s} &= \frac{T_3}{r_p^{0.2857}} = \frac{900}{1.6685} = 539.40\ \text{K} \\ T_4 &= T_3 - \eta_t (T_3 - T_{4s}) = 900 - 0.85 \times 360.60 = 593.49\ \text{K} \\ W_t &= c_p (T_3 - T_4) = 1.005 \times 306.51 = 308.04\ \text{kJ/kg} \end{aligned}

Regenerator and heat supplied

Since T4>T2T_4 > T_2, regeneration is possible:

Tx=T2+ε(T4−T2)=514.51+0.8(593.49−514.51)=577.70 KQs=cp(T3−Tx)=1.005(900−577.70)=323.92 kJ/kg\begin{aligned} T_x &= T_2 + \varepsilon (T_4 - T_2) = 514.51 + 0.8(593.49 - 514.51) = 577.70\ \text{K} \\ Q_s &= c_p (T_3 - T_x) = 1.005(900 - 577.70) = 323.92\ \text{kJ/kg} \end{aligned}

Efficiency and power

Wnet=Wt−Wc=308.04−227.64=80.40 kJ/kgηth=WnetQs=80.40323.92=0.2482=24.82%Pnet=m˙Wnet=6×80.40=482.4 kW\begin{aligned} W_{net} &= W_t - W_c = 308.04 - 227.64 = 80.40\ \text{kJ/kg} \\ \eta_{th} &= \frac{W_{net}}{Q_s} = \frac{80.40}{323.92} = 0.2482 = 24.82\% \\ P_{net} &= \dot m W_{net} = 6 \times 80.40 = 482.4\ \text{kW} \end{aligned}

For comparison, without the regenerator Qs=1.005(900−514.51)=387.42Q_s = 1.005(900 - 514.51) = 387.42 kJ/kg and η=20.75%\eta = 20.75\%, so the regenerator raises efficiency by about 4.1 percentage points.

Answer: Plant thermal efficiency = 24.82 %, net power developed = 482.4 kW (with the given data the plant cannot actually deliver its rated 800 kW at 6 kg/s).

✓ Answer checked by Claude Opus 5.5 (high effort)

All Power Plant Equipment chapter 6 questions →