Power measurement tool for airport surveillance radar

Short answer

For off-air average power, use a flow calorimeter; for online monitoring, use a calibrated directional coupler, attenuator, and thermistor power meter, then compute peak power from average and duty cycle.

Choose a proper power measurement tool to measure power of an Airport Surveillance Radar.

An Airport Surveillance Radar (ASR) is a high-power pulsed transmitter (S-band, about 2.7–2.9 GHz, peak power of the order of 1 MW, pulse width about 1 µs). A bolometer alone would burn out, so the proper choice is:

  • Flow (circulating) calorimeter wattmeter with a water-cooled dummy load to measure the full average power when the radar is off-air, and
  • in normal operation, a calibrated directional coupler + attenuator + thermistor (bolometer) power meter to sample a small known fraction of the power. Peak power is then found from average power and duty cycle (or with a peak-power diode sensor).

Set-up

Magnetron/  -> Directional coupler -> Antenna or
klystron Tx    (e.g. 50 dB)           water load
                     |                (flow calori-
                 attenuator (10 dB)    meter)
                     |
               thermistor mount -> power meter

Working principle

  1. Flow calorimeter: water flows through a matched dummy load at a known rate v. All RF power turns into heat:
P_avg = ρ · v · c · ΔT  ≈ 4.187 · v(cm³/s) · ΔT  W
  1. Coupler method: the coupler sends a fixed fraction of power (−50 dB) to the side arm; an attenuator brings it into the bolometer range (below 10 mW). The thermistor bridge reads P_meter, and:
P_avg(dBm) = P_meter(dBm) + coupling(dB)
             + attenuation(dB)
  1. Peak power of rectangular pulses:
Duty cycle D = τ × PRF
P_peak = P_avg / D

Example

Assume P_peak = 1 MW, τ = 1 µs, PRF = 1000 Hz.

  • D = 1×10⁻⁶ × 1000 = 0.001
  • P_avg = 1 MW × 0.001 = 1 kW
  • With 50 dB coupler + 10 dB attenuator (60 dB total): power at the meter = 1000 W × 10⁻⁶ = 1 mW, which suits a thermistor mount.
  • In the flow calorimeter, 1 kW with ΔT = 10 °C needs a flow of 1000/(4.186 × 10) ≈ 23.9 cm³/s of water.

Reasons for this choice

  • Calorimeter handles kW average power and is absolute and broadband.
  • The coupler method allows monitoring while the radar operates.
  • Bolometer and diode sensors are only for mW levels, so they must be used behind a coupler and attenuator.

✓ Answer checked by Claude Opus 5.5 (high effort)