- 2080 Bhadra · 8+2 marks
Double-stub on 75 Ω coax, load 109+j120 Ω
Short answer
Normalize ZL=109+j120 to zL=1.453+j1.600, yL=0.311−j0.342; short stubs, first at the load, spacing 3λ/8. Solution A lengths are l1=0.0997λ and l2=0.0464λ. The matched two-port has S11=S22=0, |S21|=1; tuner S: S11=0.568∠145.3°, S21=S12=0.823∠−37.9°, S22=0.568∠−41.1°.
A 75 Ω coaxial line is terminated with a complex load of 109 + j120 Ω. Design a double-stub matching system using short-circuited coaxial lines. Prepare its S-matrix.
Given: Z0 = 75 Ω coax, ZL = 109 + j120 Ω, short-circuited 75 Ω coaxial stubs. Assumptions: the first stub is at the load, and the stub spacing is 3λ/8.
Step 1: Normalise and convert to admittance
zL = 1.453 + j1.600
yL = 1/zL = 0.311 − j0.342
ΓL = 0.568∠41.1°, VSWR = 3.627
On the chart, zL is at 0.1930λ WTG and yL is diametrically opposite, at 0.4430λ WTG.
Step 2: First stub at the load
The first stub is placed at the load, so y1 = yL = 0.311 − j0.342.
Step 3: Forbidden-region check and rotated g = 1 circle
βd = 360° × 0.375 = 135°
g must be ≤ 1/sin²βd = 2.000
g1 = 0.3111 → matchable
Rotate the g = 1 circle by 0.375λ (270° on the chart) toward the load. The point just after stub 1 must lie on this rotated circle, so move from y1 along the constant g = 0.311 circle until it meets the rotated circle.
Step 4: Susceptance of stub 1
Analytically (Pozar), with t = tan βd:
t = tan 135° = −1.0000
b1 = −B + [1 ± √((1+t²)g − g²t²)]/t
(1+t²)g − g²t² = 0.5254, √ = 0.7248
Sol A: b1 = −1.3824
Sol B: b1 = +0.0673
Step 5: Move 0.375λ to stub 2 and find b2
Sol A: y after stub 1 = 0.311 − j1.725
(0.3320λ) → after 0.375λ: y2 = 1.000 + j3.330
b2 = −3.3302
Sol B: y after stub 1 = 0.311 − j0.275
(0.4533λ) → after 0.375λ: y2 = 1.000 − j1.330
b2 = +1.3302
Both y2 values lie on the g = 1 circle, as required.
Step 6: Stub lengths
- For a short-circuited stub: y = −j cot βl, so l = (1/2π)·cot⁻¹(−b); measure from the short-circuit point (y = ∞, right end of the chart) toward the generator.
Sol A short: l1 = 0.0997λ, l2 = 0.0464λ
Sol B short: l1 = 0.2607λ, l2 = 0.3974λ
| Quantity | Solution A | Solution B |
|---|---|---|
| Stub 1 from load | at load | at load |
| Stub spacing | 0.375λ | 0.375λ |
| b1, b2 | -1.382, -3.330 | 0.067, 1.330 |
| Short l1, l2 | 0.0997λ, 0.0464λ | 0.2607λ, 0.3974λ |
Answer (design): solution A, with l1 = 0.0997λ, l2 = 0.0464λ, and spacing 0.375λ.
Z0=75Ω 3λ/8
o------+---------------+--------[109+j120Ω]
| |
stub 2 stub 1
l2=0.0464λ l1=0.0997λ
SC SC
S-matrix
Treat the tuner (stub 2, line 0.375λ, stub 1) as a two-port with both ports referenced to Z0. Port 1 faces the generator, and port 2 faces the load. The S-parameters come from the cascaded normalised ABCD matrix [1 0; jb2 1]·[cos βd j sin βd; j sin βd cos βd]·[1 0; jb1 1], with S11 = (A + B − C − D)/Δ, S21 = 2/Δ, S22 = (−A + B − C + D)/Δ, Δ = A + B + C + D.
Before matching:
S11 = ΓL = 0.568∠41.1°, VSWR = 3.63
Tuner, solution A:
S11 = 0.568∠145.3° S12 = 0.823∠-37.9°
S21 = 0.823∠-37.9° S22 = 0.568∠-41.1°
S12 = S21 (reciprocal), |S11|²+|S21|² = 1 (lossless)
S22 = ΓL* (conjugate match)
After matching (tuner + load):
Γin = S11 + S12S21ΓL/(1 − S22ΓL) = 0, VSWR = 1
Referred to the load (port 2 normalised to ZL), the perfectly matched network is S = [0 e^(−jφ); e^(−jφ) 0]. S11 = S22 = 0, and |S21| = 1, so all power reaches the load.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Double-stub on 75 Ω coax, load 0.4+j0.85 · RF and Microwave Engineering, chapter 2
- Matching techniques and double-stub S-matrix · RF and Microwave Engineering, chapter 2
- Double-stub for inductive antenna load on 78 Ω line · RF and Microwave Engineering, chapter 2
- Double-stub matching 110+j110 Ω on 100 Ω line · RF and Microwave Engineering, chapter 2 · asked 2×
- Double-stub tuner for 75+j75 Ω on 50 Ω line · RF and Microwave Engineering, chapter 2 · asked 2×
- Open-circuited double stub for 60−j80 Ω · RF and Microwave Engineering, chapter 2