Short answer

SS7 is a four-level stack: MTP1 physical, MTP2 data link, MTP3 plus SCCP network, and TCAP/ISUP/TUP application; ISUP and TUP use MTP3 directly. MTP2 gives reliable links using flags, 16-bit CRC, sequence numbers, retransmission, alignment and error monitoring. Its signal units are MSU (SIO/SIF messages), LSSU (link status field) and FISU (fill-in, LI=0).

Compare the SS7 protocol stack with the OSI layers. Describe the purpose and the format of the signal units transferred by the second message transfer part (MTP-L2).

SS7 vs OSI layers

OSI layerSS7 equivalentFunction
1 PhysicalMTP Level 164 kb/s signaling data link
2 Data linkMTP Level 2Error control, sequencing, flags
3 NetworkMTP Level 3 + SCCPRouting by point code; global title
4–6(none; TCAP covers part)Not separately defined
7 ApplicationTCAP, ISUP, TUP, MAP, OMAPCall control and database queries

ISUP and TUP sit directly on MTP-3 (they skip SCCP), so SS7 is a 4-level stack rather than a strict 7-layer one.

Purpose of MTP Level 2

MTP-2 makes a single signaling link reliable: it delimits units with flags, detects errors with a 16-bit CRC, keeps the order with sequence numbers, retransmits lost or errored units, aligns a new link, and monitors the error rate so a bad link is taken out of service. Three kinds of signal units (SU) are used.

1. Message Signal Unit (MSU)

Carries real signaling messages from MTP-3 users (ISUP, SCCP, network management).

| F | BSN|BIB| FSN|FIB| LI |Sp| SIO |   SIF    | CK | F |
| 8 |  7 | 1 |  7 | 1 | 6  |2 |  8  | 8n, n>=2 | 16 | 8 |

2. Link Status Signal Unit (LSSU)

Carries link status (alignment, out of service, processor outage, busy) in a Status Field (SF) of 8 or 16 bits in place of SIO+SIF.

3. Fill-In Signal Unit (FISU)

Sent when there is no traffic, to keep the link synchronised and to carry acknowledgements; it has no SIO/SIF (LI = 0).

Fields

  • F (Flag): 01111110, opens and closes each unit.
  • BSN / BIB: backward sequence number and indicator bit, used to acknowledge or ask for retransmission (BIB inverted = negative ack).
  • FSN / FIB: forward sequence number of this unit and its indicator bit.
  • LI (Length Indicator): number of octets after LI: 0 = FISU, 1 or 2 = LSSU, 3 or more = MSU (63 if above 62).
  • SIO (Service Information Octet): service indicator (which user: SNM, SCCP, TUP, ISUP) and network indicator (national/international).
  • SIF (Signaling Information Field): routing label (DPC, OPC, SLS) and user data, up to 272 octets.
  • CK: 16-bit CRC check bits.

✓ Answer checked by Claude Opus 5.5 (high effort)