- 2082 Baisakh · 4 marks
Controller recommended to reduce steady-state error
Short answer
Use a PI controller (or lag compensator) because it adds a pole at the origin, increasing the system type by one. The integral term grows while any error remains, driving steady-state error to zero for step or ramp inputs.
Which type of controller do you recommend to reduce the steady state error? Explain.
To reduce (or eliminate) steady-state error, an integral-type controller, usually a PI controller (or PID), is recommended. In frequency-domain design, the equivalent is a lag compensator.
Why integral action
The steady-state error of a unity feedback system depends on the system type and the error constants:
where is the position error constant and the velocity error constant.
A PI controller
adds a pole at the origin, so the system type increases by one:
| Plant type | Without PI | With PI |
|---|---|---|
| 0 | finite step error | zero step error |
| 1 | finite ramp error | zero ramp error |
Physically, the integral keeps growing while any error remains, so the controller output keeps changing until the error is exactly zero.
The zero at is placed close to the origin so that the extra phase lag (and its effect on the transient response and stability) stays small.
Alternatives
- Increasing proportional gain reduces the error but cannot remove it, and makes the response oscillatory.
- Lag compensator raises the low-frequency gain by ( multiplied by β) without changing the transient much.
Example: with unity-gain P control has and step error . With PI control the open loop has a pole at the origin and the step error becomes zero.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- True/false: proportional controller makes error zero · Control Systems, chapter 7
- Velocity feedback increases ζ and steady-state error · Control Systems, chapter 3
- Controller to change transient properties · Control Systems, chapter 7
- Error constants of 108/[s²(s+4)(s²+3s+12)], r = 2+5t+8t² · Control Systems, chapter 3 · asked 4×
- Error constants of 108/[s²(s+4)(s²+3s+12)], r = 2+5t+2t² · Control Systems, chapter 3 · asked 4×
- Error constants of 5/[s(s+2)(s²+2s+8)], r = 2+5t+2t² · Control Systems, chapter 3 · asked 4×
- Case study: recommended changes and convincing · Instrumentation II, chapter 10 · asked 2×
- Compensation does not reduce load reactive demand · Power System Analysis I, chapter 6
- Steady state vs transient stability; enhancement · Power System Analysis II, chapter 6 · asked 2×
- Force by vane on steady stream · Applied Mechanics (Dynamics), chapter 3