Open and closed loop systems with block diagram

Short answer

Open-loop systems have no feedback; control action is independent of output. Closed-loop systems measure output, compare with reference, and use the error to drive the plant. Components: reference input, error detector, controller, actuator, plant, feedback sensor, and disturbance input. Feedback gives accuracy and disturbance rejection.

What are open loop and closed loop control systems? Draw the block diagram of closed loop control system and explain the role of each block.

Open-loop control system

A system in which the control action does not depend on the output. The output is neither measured nor fed back.

 r   +------------+  u   +-------+   c
---->| Controller |----->| Plant |------>
     +------------+      +-------+

Examples: electric toaster with timer, washing machine on timer, fixed-time traffic lights. They are simple and cheap but cannot correct errors caused by disturbances or parameter changes.

Closed-loop control system

A system in which the output is measured and fed back to the input, and the control action depends on the error between the desired and actual output. Examples: room air conditioner with thermostat, motor speed control with tachometer, voltage regulator.

                       disturbance d
                            |
 r   +----+  e   +------+ u +---+---+   c
---->| Σ  |----->|Contr-|-->| Plant |----+---->
     +----+      | oller|   +-------+    |
      - ^        +------+                |
        |  b    +-----------------+      |
        +-------| Feedback/sensor |<-----+
                +-----------------+

Role of each block

  1. Reference input rr (set point): desired value of the output.
  2. Error detector / summing point: compares rr with feedback bb and gives error e=r−be = r - b.
  3. Controller: acts on the error (P, PI, PID) and produces control signal uu.
  4. Actuator: power element (motor, valve, amplifier) that applies uu to the plant.
  5. Plant / process: the system being controlled; gives the controlled output cc.
  6. Disturbance dd: unwanted input acting on the plant (load change, noise).
  7. Feedback element / sensor: measures cc and converts it to bb, comparable with rr.

The overall transfer function is C(s)R(s)=G(s)1+G(s)H(s)\dfrac{C(s)}{R(s)} = \dfrac{G(s)}{1+G(s)H(s)}, where GG is the forward path (controller, actuator, plant) and HH the feedback element.

Comparison

PointOpen loopClosed loop
Feedbackabsentpresent
Accuracydepends on calibrationhigh
Disturbance effectfully at outputreduced by 1+GH1+GH
Stabilitygenerally stablemay become unstable
Cost, complexitylowhigher
Exampletoasterair conditioner