- 2068 Baisakh · 10 marks
Smith chart, load 100+j150 on 75 Ω line
Short answer
Normalize load to z_L = 1.333 + j2.0. On Smith chart, reflection coefficient circle gives |Γ| = 0.66 at 39.9°. VSWR = 4.88. Rotate 180° for y_L = 0.231 − j0.346 (Y_L = 3.08 − j4.62 mS). Move 0.4λ toward generator: Z_in = 22 + j47.6 Ω. For 0.6λ line (equivalent 0.1λ): Z_in = 133.6 − j165.7 Ω.
A load of 100 + j150 Ω is connected to a 75 Ω lossless line. Find using Smith Chart: (a) reflection coefficient (b) VSWR (c) the load admittance (d) Z_in at 0.4λ from the load (e) Z_in at generator if the line is 0.6λ long.
Given: Z_L = 100 + j150 Ω, Z₀ = 75 Ω. Normalised load:
z_L = Z_L/Z₀ = 1.333 + j2.0
Plot z_L (r = 1.33 circle, x = +2 arc). With the compass centred on the chart centre, draw the circle through z_L.
(a) Reflection coefficient
Read |Γ| from the radial scale and the angle from the angle-of-reflection scale:
Γ = (z_L − 1)/(z_L + 1) = (0.333 + j2)/(2.333 + j2)
= 2.028∠80.5° / 3.073∠40.6°
= 0.660 ∠39.9°
(b) VSWR
Where the |Γ| circle cuts the right side of the real axis:
VSWR = (1 + 0.660)/(1 − 0.660) = 4.88 ≈ 4.9
(c) Load admittance
Draw the diameter through z_L and read the opposite point on the same circle (rotate 180° = λ/4):
y_L = 1/z_L = 0.231 − j0.346
Y_L = y_L/Z₀ = (0.231 − j0.346)/75 = 3.08 − j4.62 mS
(d) Z_in at 0.4λ from the load
Move 0.4λ toward the generator (clockwise); the angle of Γ becomes 39.9° − 2×360°×0.4 = 39.9° − 288° = −248.1° ≡ 111.9°. Reading the chart at this point:
z_in ≈ 0.29 + j0.64 → Z_in = 75 × z_in ≈ 22 + j47.6 Ω (52.4∠65.2°)
Check by formula with βl = 144°: Z_in = 21.97 + j47.61 Ω.
(e) Z_in at the generator, line 0.6λ long
0.6λ is more than a half wavelength; the chart repeats every 0.5λ, so it is the same as 0.1λ:
Angle of Γ = 39.9° − 72° = −32.1°.
z_in ≈ 1.78 − j2.21 → Z_in = 75 × z_in ≈ 133.6 − j165.7 Ω (212.9∠−51.1° Ω)
Answer: (a) 0.66∠39.9°; (b) 4.88; (c) y_L = 0.231 − j0.346 (Y_L = 3.08 − j4.62 mS); (d) 22 + j47.6 Ω; (e) 133.6 − j165.7 Ω.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Smith chart, load 80+j100 on 50 Ω line · Electromagnetism, chapter 5
- Lossless line, L Z0 β Γ · Electromagnetism, chapter 5
- Line with 50+j50 load, first maximum, power · Electromagnetism, chapter 5
- 30 m line at 2 MHz, Γ SWR Zin · Electromagnetism, chapter 5
- Smith chart analysis of 75+j100 Ω load · RF and Microwave Engineering, chapter 2
- Double-stub shunt tuner for admittance load · RF and Microwave Engineering, chapter 2
- Admittance chart and single stub for 80+j100 Ω · RF and Microwave Engineering, chapter 2
- 6° phase shift per 100 km of lossless line · High Voltage Engineering, chapter 3