Series motor load start; shunt motor speed control

Short answer

A series motor cannot start without load because low armature current yields minimal flux, leading to dangerously high speed. Shunt motor speed control methods: armature rheostat control reduces speed below base (high loss, constant torque); field control increases speed above base (efficient, constant power); armature voltage control provides 0 to base speed.

Explain why the dc series motor can not be started without some mechanical load. Also discuss the armature control and field control method for speed control of dc shunt motor.

Why a series motor cannot be started without load

In a series motor the field winding carries the armature current, so the flux depends on the load: Φ∝Ia\Phi\propto I_a (below saturation). The speed is

N∝EbΦ≈V−Ia(Ra+Rse)ΦN \propto \frac{E_b}{\Phi} \approx \frac{V - I_a(R_a + R_{se})}{\Phi}
  • At no load IaI_a becomes very small, so the flux Φ\Phi becomes very small (only the residual value).
  • The numerator Eb≈VE_b\approx V stays nearly constant, so the speed N∝1/ΦN\propto 1/\Phi rises to a dangerously high value (several times rated speed).
  • This is called racing. The centrifugal forces can burst the armature, throw the winding out of the slots and damage the commutator and bearings.
  • The torque T∝ΦIa∝Ia2T\propto\Phi I_a\propto I_a^2 is small at no load, so the motor has no load to hold the speed down.

Hence a series motor must always be started and run with a load connected (preferably directly coupled or geared, never by a belt that may slip or break).

Speed control of a DC shunt motor

From the motor equations:

N=V−IaRaKΦ∝EbΦN = \frac{V - I_aR_a}{K\Phi} \propto \frac{E_b}{\Phi}

So the speed of a shunt motor can be changed by varying the flux Φ\Phi, the armature circuit resistance, or the applied voltage.

1. Armature (rheostatic) control

A variable resistance RxR_x is connected in series with the armature (field kept constant at full value):

N=V−Ia(Ra+Rx)KΦN = \frac{V - I_a(R_a + R_x)}{K\Phi}
  • The speed is reduced below the normal (base) speed; the greater RxR_x, the lower the speed.
  • Torque for a given IaI_a is unchanged (T∝ΦIaT\propto\Phi I_a), so it suits constant-torque loads.
  • Disadvantages: large Ia2RxI_a^2R_x loss, poor efficiency, and poor speed regulation (the speed changes with load); it is used for small and short-time duty.

2. Field (flux) control

A rheostat RfR_f is connected in series with the shunt field:

If=VRsh+Rf,N∝1ΦI_f = \frac{V}{R_{sh} + R_f}, \qquad N \propto \frac{1}{\Phi}
  • Increasing RfR_f lowers Φ\Phi, so the speed rises above the base speed (typically up to 2:1 or 3:1).
  • It is simple, cheap and efficient (field loss is small, since IfI_f is small).
  • Limits: commutation worsens and the machine can become unstable (armature reaction) at very weak fields; the torque for a given IaI_a falls as Φ\Phi falls, so it suits constant-power loads.
   Speed
     ^       field control (N up)
     |      /
  base N ---+--- 
     |      \  armature control (N down)
     +--------------------> Rheostat setting

3. Armature voltage control (Ward-Leonard)

Varying the voltage applied to the armature (with a separate source) changes the speed smoothly from zero up to the base speed.

Comparison

PointArmature controlField control
Speed rangebelow base speedabove base speed
Losshigh (Ia2RxI_a^2R_x)low
Efficiencypoorgood
Load suitedconstant torqueconstant power
Speed regulationpoorgood