- 2067 Mangsir (old course) · 8 marks
Star-delta starting torque ratio and full-load slip
Short answer
Slip at maximum torque = 0.1. Direct start torque ratio to full load = 0.495. With star-delta starter, ratio = 0.165. Full-load slip = 0.0209.
A 3-ph induction motor has a ratio of maximum torque to full load torque as 2.5:1. Determine the ratio of actual starting torque to full load torque for star delta starting. Also calculate full load slip. [Given: rotor resistance per phase = and rotor reactance per phase at stand still = ]
Given: , , at standstill.
Slip at maximum torque
Starting torque with direct switching
Star-delta starting
In star, the phase voltage is of the line voltage, and torque , so the starting torque is one third of the direct (delta) value:
Full-load slip
Answer: starting torque with star-delta starter ; full-load slip (2.09 %).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Slip for maximum torque and full-load output of slip ring motor · Electrical Machines I, chapter 5 · asked 2×
- Delta induction motor: slip, rotor emf, turns ratio · Electrical Machines, chapter 5 · asked 2×
- Starting, no-load and full-load current of slip ring motor · Electrical Machines I, chapter 5
- Slip ring motor: starting, no-load, full-load currents · Electrical Machines, chapter 5
- Slip ring motor max-torque slip and full-load output · Electrical Machines I, chapter 5 · asked 4×
- Slip at max torque and full load, starting current · Electrical Machines, chapter 5
- Delta IM slip, rotor frequency, turns ratio · Electrical Machine, chapter 5
- Torque of 4-pole induction motor at 1400 rpm · Electrical Machines I, chapter 5
- IM slip and starting current from torque ratios · Electrical Machine, chapter 5
- Max-torque speed and efficiency of 400 V slip ring motor · Electrical Machines I, chapter 5 · asked 2×