At small slip, sX2 is much less than R2, so T is proportional to slip and the curve is linear. This region is stable because a load increase raises slip and torque until equilibrium; beyond maximum torque, torque falls with slip, causing stalling, and rotor copper loss and efficiency also favor low-slip operation.

Explain torque slip characteristics of 3-phase induction motor. Why the induction motor operates only in linear portion of torque-slip characteristics?

Torque-slip characteristics

The torque produced by a three-phase induction motor at slip ss is

T=3ωs⋅sE22R2R22+(sX2)2T = \frac{3}{\omega_s}\cdot\frac{s E_2^2 R_2}{R_2^2 + (sX_2)^2}

The curve starts at TstT_{st} for s=1s=1, rises to TmaxT_{max} at sm=R2/X2s_m = R_2/X_2, then drops to zero at s=0s=0.

 T
 |          Tmax
 |        _.-*-._
 |  Tst _-'      `-._
 |   *-'              `-.
 |                        `-.
 +--+--------+--------------*--> s
  s=1       s_m   linear   s=0
          (unstable)(stable)
  • Between s=1s=1 and sms_m the torque falls as slip rises (T∝1/sT \propto 1/s): unstable.
  • Between sms_m and 00 the torque is nearly proportional to slip (T∝sT \propto s): stable and almost linear.
  • The maximum torque is Tmax=3E222ωsX2T_{max} = \frac{3E_2^2}{2\omega_s X_2}.

Why the motor operates only in the linear portion

  1. For small slip, sX2≪R2sX_2 \ll R_2, so T≈3E22ωsR2s∝sT \approx \frac{3E_2^2}{\omega_s R_2}s \propto s. The curve is a straight line.
  2. In this region, if the load rises, the speed falls slightly, the slip rises and the torque increases in proportion. A new equilibrium is reached quickly, so the operation is stable.
  3. Beyond sms_m, a rise in load makes the speed fall, which reduces the torque, so the speed falls further and the motor stalls. The operation is unstable.
  4. In the linear region the rotor resistance dominates the rotor reactance (R2≫sX2R_2 \gg sX_2), so the rotor power factor is nearly unity. The slip is small (2 to 5 %), so the rotor copper loss (=sPg= sP_g) is small and the efficiency is high.
  5. The speed remains almost constant (close to NsN_s) from no load to full load, which is the behaviour most drives need.

So the motor is run in the low-slip region of the curve, with full-load slip well below sms_m.