Testing of DC machines: retardation vs Swinburne's test
Short answer
Testing determines losses, efficiency, heating, commutation and characteristics without full-load testing. Swinburne's test runs the machine as a shunt motor on no load and measures constant losses from electrical input. Retardation test cuts armature supply and measures deceleration to find rotational losses and separate iron and mechanical losses using moment of inertia.
Explain the necessity of testing in DC machines. Explain how is the retardation test different from the Swinburne's test?
Necessity of testing DC machines
Testing is done to find the performance of a DC machine without (or before) putting it in service:
- To find losses (constant and variable) and hence efficiency at any load.
- To check temperature rise and heating under load, which decides the rating.
- To check commutation and sparking at the brushes.
- To find characteristics (OCC, load and speed-torque curves) and confirm the design and name-plate values.
- For acceptance and quality control by manufacturer and buyer.
Direct loading of large machines wastes much energy and needs a large load, so indirect tests such as Swinburne's (no-load) test and the retardation test are used.
Swinburne's test
The machine runs as a shunt motor on no load at rated voltage and speed. The input minus the small no-load armature copper loss gives the constant losses (iron + friction and windage + shunt field copper loss) directly. The efficiency at any load is then calculated.
Retardation (running-down) test
The machine is run above rated speed and the supply to the armature is cut off (field kept excited for iron loss). The armature slows down as its stored kinetic energy supplies the rotational losses. The time taken to fall through a known speed range (say 1.1 to 0.9 ) is measured:
is found by repeating the test with a known extra load (or an added flywheel). Running down with the field off gives the mechanical loss alone, so the iron loss can be separated.
Difference
| Point | Swinburne's test | Retardation test |
|---|---|---|
| Machine state | Running as motor on no load | Armature disconnected, coasting down |
| Measurement | Electrical: , , | Speed vs time (slope ) |
| Losses obtained | Total constant (stray) losses | Rotational losses; mechanical and iron separately |
| Need of | Not needed | Moment of inertia must be known or found |
| Machines | Shunt and compound only | Shunt machines; also large machines with good inertia |
| Accuracy | Ignores stray load loss and temperature change | Also ignores stray load loss; depends on speed reading accuracy |
| Power needed | Small no-load power | Almost none (uses stored energy) |
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Armature reaction in DC machines and its remedies · Electrical Machines I, chapter 3
- Self-excited vs separately excited DC generators · Electrical Machines I, chapter 3
- Need of DC motor starter and three-point starter · Electrical Machines I, chapter 4 · asked 4×
- Back emf and its role in DC motor · Electrical Machines I, chapter 4 · asked 6×
- DC current for iron ring with 4 mm air gap · Electrical Machines I, chapter 1
- DC current for iron rod ring with 4 mm air gap · Electrical Machines I, chapter 1
- Test: soft drink filling machines · Probability and Statistics, chapter 6
- Test: steel rod diameters on two machines · Probability and Statistics, chapter 6
- Point vs interval estimation; estimation vs testing · Probability and Statistics, chapter 6
- Estimation vs testing; CI for hardness · Probability and Statistics, chapter 6