Self-excited vs separately excited DC generators

Short answer

Separately excited: field from external source; self-excited: field from own armature, needs residual flux. Self-excited types: shunt (Ia=IL+Ish, Eg=V+IaRa), series (Ia=IL, Eg=V+Ia(Ra+Rse)), compound (long-shunt: Ish=V/Rsh, Ia=IL+Ish; short-shunt: Ish=(V+ILRse)/Rsh, Ia=IL+Ish).

Distinguish between self-excited and separately excited d.c generators. How are self-excited d.c. generators classified? Give their circuit diagrams and respective equations.

A DC generator needs a magnetic field from its field winding. If the field current comes from an external DC source, the generator is separately excited. If the field current comes from the generator's own armature, it is self-excited; it builds up voltage from the residual magnetism of the poles.

Self-excited vs separately excited

PointSeparately excitedSelf-excited
Field supplyExternal battery or DC sourceOwn armature output
Residual magnetismNot neededEssential for voltage build-up
Voltage build-upAlways, as soon as field is fedOnly if field resistance < critical value and polarity is correct
Voltage regulationBetter (field current fixed)Poorer in shunt type (field current falls with V)
Cost and setupNeeds extra source, costlySimple, no extra source
UsesLab tests, Ward-Leonard, wide voltage controlGeneral supply, battery charging, welding, boosters

Classification of self-excited generators

Depending on how the field winding is connected to the armature:

  1. Shunt generator
  2. Series generator
  3. Compound generator – (a) long shunt, (b) short shunt; each can be cumulative or differential.

1. Shunt generator

Field winding (many turns of thin wire, high resistance) is connected in parallel with the armature.

   +---Ra---+------+
   |        |      |
  (Eg)     Rsh   Load  V
   |        |      |
   +--------+------+
Ia=IL+Ish,Ish=VRsh,Eg=V+IaRa+VbI_a = I_L + I_{sh}, \quad I_{sh} = \frac{V}{R_{sh}}, \quad E_g = V + I_a R_a + V_b

2. Series generator

Field winding (few turns of thick wire, low resistance) is in series with the armature and load.

   +---Ra---Rse---+
   |              |
  (Eg)          Load  V
   |              |
   +--------------+
Ia=Ise=IL,Eg=V+Ia(Ra+Rse)+VbI_a = I_{se} = I_L, \quad E_g = V + I_a (R_a + R_{se}) + V_b

3. Compound generator

Has both shunt and series fields.

Long shunt: shunt field across the series combination of armature and series field.

   +--Ra--Rse--+------+
   |           |      |
  (Eg)        Rsh   Load
   |           |      |
   +-----------+------+
Ish=VRsh,Ia=Ise=IL+Ish,Eg=V+Ia(Ra+Rse)+VbI_{sh} = \frac{V}{R_{sh}}, \quad I_a = I_{se} = I_L + I_{sh}, \quad E_g = V + I_a (R_a + R_{se}) + V_b

Short shunt: shunt field directly across the armature only.

   +--Ra--+----Rse----+
   |      |           |
  (Eg)   Rsh        Load
   |      |           |
   +------+-----------+
Ise=IL,Ish=V+ILRseRsh,Ia=IL+Ish,Eg=V+ILRse+IaRa+VbI_{se} = I_L, \quad I_{sh} = \frac{V + I_L R_{se}}{R_{sh}}, \quad I_a = I_L + I_{sh}, \quad E_g = V + I_L R_{se} + I_a R_a + V_b

In a cumulative compound generator the series flux aids the shunt flux; in a differential one it opposes it. Here VbV_b is the total brush drop.