Skip to main content

Hydro and thermal power sources

Short answer

Hydropower uses water head and flow to drive a turbine (P=ηρgQH), with free fuel, high efficiency (85-90%), low running cost, but high capital. Thermal power burns fuel to produce steam for a turbine (Rankine cycle), with lower efficiency (30-40%), high fuel cost, pollution, and slow start.

Describe in brief hydro and thermal power sources with basic principles of electricity generation and major features.

Hydropower

Principle: Water stored at a height has potential energy. It flows through a penstock to a turbine, which turns an alternator. Power:

P=ηρgQH WP = \eta\rho gQH\ \text{W}

where QQ = flow (m³/s), HH = net head (m), η\eta = overall efficiency.

 Dam/Intake -> Headrace -> Surge tank -> Penstock
     -> Turbine --[Generator]--> Tx -> Grid
     -> Tailrace -> River

Major features

  • Fuel is free; very low running cost; renewable and non-polluting.
  • High efficiency (85–90 %) and long life (50+ years).
  • Quick start and load change: useful for peak load and frequency control.
  • High initial cost and long construction time; site depends on geography; often far from load centres.
  • Output varies with season (run-of-river plants drop in dry season).
  • Examples: Kali Gandaki A (144 MW), Upper Tamakoshi (456 MW).

Thermal (steam) power

Principle: Fuel (coal, oil, gas) is burned in a boiler; the heat turns water into high-pressure steam, which expands in a steam turbine coupled to an alternator, then is condensed and pumped back (Rankine cycle). Chemical energy → heat → mechanical → electrical energy.

 Fuel -> [Boiler] -> steam -> [Turbine]--[Gen]-> Grid
            ^                    |
       [Feed pump] <- [Condenser] <- cooling water

Major features

  • Lower initial cost and shorter construction; can be built near loads or fuel source.
  • High running cost due to fuel; overall efficiency only 30–40 %.
  • Pollution: CO₂, SO₂, NOx, ash; needs chimneys, precipitators and ash disposal.
  • Needs large amounts of cooling water.
  • Slow start; best for base load.
FeatureHydroThermal
Fuel costNilHigh
Efficiency85–90 %30–40 %
Capital costHighLower
PollutionVery lowHigh
StartingQuickSlow
Load typeBase and peakBase

✓ Answer checked by Claude Opus 5.5 (high effort)