- 2078 Baisakh · 2 marks
Draw UCS and direct shear results
Short answer
For UCS, plot axial stress vs strain to get qu, then draw Mohr circle through origin with diameter qu; the horizontal tangent gives cu = qu/2. For direct shear, plot shear stress vs displacement for each normal stress, then plot peak shear strength vs normal stress to obtain c and φ from the best-fit line.
Draw final test results of the Unconfined Compression Test and the Direct Shear Test for the same soil so that the strength parameters of the soil could be obtained.
Unconfined compression test (UCS)
Plot axial stress against axial strain; the peak is . The Mohr circle drawn on the - plane passes through the origin () with , and the envelope is a horizontal line tangent to the circle for :
UCS stress-strain Mohr circle
s1 tau
| ___ qu | ..--..
| / \ cu |--*' '*--
| / | / C \
+--------- strain -+-+--------+--- sigma
0 (s3=0) qu
Direct shear test
Plot shear stress against horizontal displacement for each normal stress to get the peak . Then plot against normal stress for three or more tests and draw the best-fit straight line:
tau_f /
| / <- slope = phi
| /
c |--------/
| .
+--------------- sigma
s1 s2 s3
Intercept ; slope angle . For the same clay, the UCS gives (total stress, quick), while the direct shear (slow) gives and under drained conditions.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- UCS test soil type and parameters · Soil Mechanics, chapter 10
- Limitations of direct shear test · Soil Mechanics, chapter 10
- UCS as special case of UU test · Soil Mechanics, chapter 10
- Shear tests; direct shear calculation · Soil Mechanics, chapter 10
- Triaxial tests by drainage; UCS vs cu · Soil Mechanics, chapter 10
- Triaxial advantage over direct shear · Soil Mechanics, chapter 10
- Characteristic strength from test results · Concrete Technology and Masonry Structure, chapter 5
- Stress on oblique section with direct and shear stress · Strength of Materials, chapter 4
- Diagonal shear test and flat-jack test calculations · Design of Timber and Masonry Structures, chapter 8
- 20 kVA 250/2500 V test parameters · Electrical Machine, chapter 2 · asked 2×