- Asked 4/22
- 2080 Bhadra · 6 marks
Main dimensions of 30 kW 220 V shunt generator
Short answer
Ia=138.2 A, E=226.6 V, Pa=31.32 kW. Co=117.4, D²L=0.01778 m³. Square pole face yields D=0.319 m, L=0.175 m.
A design is required for a 30 kW, 4 pole, 900 rpm dc shunt generator, the full load terminal voltage being 220 V. Assume that the full load armature voltage is 3% of the terminal voltage. Calculate the main dimensions of the machine if the maximum gap density is 0.85 Wb/m², specific electrical loading of 20,000 ampere conductor/meter and field resistance is 120 Ω. The ratio of pole arc to pole pitch is 0.7.
The main dimensions come from the output equation of a dc machine (A.K. Sawhney):
where = armature power (kW), = armature diameter, = core length (m), = speed (rps).
The question does not state a length condition, so the usual assumption is made: square pole face (core length = pole arc). The full-load armature voltage drop is taken as 3% of terminal voltage.
Step 1: Armature power from currents and emf
Step 2: Loadings and
Step 3: Square pole face
Check
- Pole pitch m; pole arc m .
- Peripheral speed m/s; frequency Hz. Both acceptable.
Answer: Armature diameter m, armature core length m.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- 30 kW 240 V generator, square pole · Electric Machine Design, chapter 5 · asked 2×
- 30 kW 240 V generator, 3% drop · Electric Machine Design, chapter 5 · asked 3×
- 30 kW 240 V generator, 2.5% drop · Electric Machine Design, chapter 5 · asked 3×
- Armature dimensions of 50 kW shunt generator · Electric Machine Design, chapter 5
- Main dimensions of 600 kW square-pole generator · Electric Machine Design, chapter 5
- Main dimensions of 200 kW shunt generator · Electric Machine Design, chapter 5
- Armature size, 10 kW 900 rpm motor · Electric Machine Design, chapter 5 · asked 5×
- Main dimensions of 5 kW generator (Bav 0.42) · Electric Machine Design, chapter 5 · asked 4×
- Main dimensions of 5 kW generator (Bav 0.40) · Electric Machine Design, chapter 5 · asked 4×
- Short shunt to long shunt compound generator (10 kW, 220 V) · Electrical Machines I, chapter 3
- 30 kW shunt generator: emf, copper loss, efficiency · Electrical Machines, chapter 3 · asked 2×
- 30 kW shunt generator: emf, copper loss, efficiency (100 W) · Electrical Machines, chapter 3 · asked 2×
- EMF, copper loss and efficiency of 30 kW shunt generator · Electrical Machines I, chapter 3