- 2081 Bhadra · 8 marks
Main dimensions of 200 kW shunt generator
Short answer
Pa=(1+2η)/(3η)×P=206.6 kW, Co=178.3, D²L=0.0695 m³. Using L/τ=0.75 gives L=0.3927D, thus D=0.561 m, L=0.220 m.
Find the main dimensions of a 200 kW, 250 V, 6 pole, 1000 rpm dc shunt generator. The maximum value of flux density in the gap is 0.87 Wb/m² and ampere conductors per meter of armature periphery are 31,000. The ratio of pole arc to pitch is 0.67 and the efficiency is 91 percent. Assume the ratio of length of core to pole pitch is 0.75.
The main dimensions come from the output equation of a dc machine (A.K. Sawhney):
where = armature power (kW), = armature diameter, = core length (m), = speed (rps).
For a generator, taking armature copper loss as about one-third of total losses (Sawhney),
Step 1: Armature power
Step 2: Loadings and output coefficient
Step 3: Use
Check
- Pole pitch m; pole arc m.
- Peripheral speed m/s (within the usual 30 m/s limit).
- Frequency Hz (acceptable).
Answer: Armature diameter m, core length m.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Armature dimensions of 50 kW shunt generator · Electric Machine Design, chapter 5
- Main dimensions of 5 kW generator (Bav 0.42) · Electric Machine Design, chapter 5 · asked 4×
- Main dimensions of 5 kW generator (Bav 0.40) · Electric Machine Design, chapter 5 · asked 4×
- Main dimensions of 30 kW 220 V shunt generator · Electric Machine Design, chapter 5 · asked 4×
- 1000 kW generator: dimensions, poles, air gap · Electric Machine Design, chapter 5
- 600 kW generator: dimensions, poles, air gap · Electric Machine Design, chapter 5
- Long shunt compound generator speed, 300 conductors · Electrical Machines, chapter 3 · asked 2×
- 4-pole shunt generator, wave wound, 3 kW · Electrical Machines, chapter 3 · asked 3×
- 4-pole shunt generator, 3 kW at 120 V · Electrical Machine, chapter 3 · asked 2×
- EMF of short shunt compound generator (6 kW, 250 V) · Electrical Machines I, chapter 3