4-pole shunt generator, wave wound, 3 kW
Short answer
Load current I_L = 3000/120 = 25 A, shunt field current I_sh = 120/60 = 2 A, so armature current I_a = 27 A. Wave winding has 2 parallel paths, so conductor current = 27/2 = 13.5 A. Generated emf E = V + I_a R_a + brush drop = 120 + 27×0.2 + 2 = 127.4 V.
A 4-pole dc shunt generator has wave wound armature. The armature and field winding resistances are and respectively. The brush contact drop is 1 volt per brush. The generator is delivering a power of 3 kW at 120 V. Calculate: (a) Total armature current coming out from the brush. (b) Current in each armature conductor. (c) Generator EMF (E).
In a shunt generator the armature current supplies both the load and the field: . The generated emf must also cover the armature drop and the brush drop.
(a) Armature current
Load current:
Shunt field current:
(b) Current in each armature conductor
A wave winding has parallel paths regardless of the number of poles.
(c) Generated emf
Brush drop .
Answer: (a) ; (b) current per conductor ; (c) .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- EMF of 25 kW short shunt generator with brush drop · Electrical Machines I, chapter 3
- Wave-wound shunt generator, power absorbed by load · Electrical Machines, chapter 3
- Long shunt compound generator speed, lap and wave · Electrical Machines, chapter 3 · asked 2×
- Shunt generator feeding six lamps · Electrical Machines I, chapter 3
- Short shunt compound generator with heater load · Electrical Machines, chapter 3
- Starting current; speed and % drop of shunt motor · Electrical Machines, chapter 4
- 4-pole shunt generator, 3 kW at 120 V · Electrical Machine, chapter 3 · asked 2×
- Armature dimensions of 50 kW shunt generator · Electric Machine Design, chapter 5
- 30 kW 240 V generator, 2.5% drop · Electric Machine Design, chapter 5 · asked 3×
- 30 kW 240 V generator, 3% drop · Electric Machine Design, chapter 5 · asked 3×