Long shunt compound generator speed, lap and wave
Short answer
With 40 A load at 250 V, shunt field current 1 A, armature current 41 A, generated emf = 260.25 V. For lap winding (300 conductors, A=4): speed = 1041.0 rpm. For wave winding (A=2): speed = 520.5 rpm.
A 4 pole, 250 V dc long shunt compound generator supplies a load of 10 kW at rated voltage. The armature, series field and shunt field resistances are , and respectively. The armature is lap wound with 50 slots, each slot containing 6 conductors. If the flux per pole is 50 mWb, calculate the speed of generator. What would be the speed of same generator if armature is wave wound?
In a long shunt compound generator the shunt field is across the armature plus series field combination (i.e. across the load terminals), so the series field carries the armature current.
Ia Rse
+--->---[~~~~]---+---------+----o +
| | |
(E,Ra) [Rsh] Load
| | |
+----------------+---------+----o -
Currents
Generated emf
Speed with lap winding
Slots conductors per slot: . For lap winding .
Speed with wave winding
For wave winding ; , , and are unchanged.
The wave-wound machine needs only half the speed because it has half the parallel paths (twice the conductors in series per path).
Answer: lap wound: ; wave wound: . (Brush drop is not given, so it is neglected.)
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Long shunt compound generator speed, 300 conductors · Electrical Machines, chapter 3 · asked 2×
- 4-pole shunt generator, wave wound, 3 kW · Electrical Machines, chapter 3 · asked 3×
- Short shunt to long shunt compound generator (10 kW, 220 V) · Electrical Machines I, chapter 3
- EMF of short shunt compound generator (6 kW, 250 V) · Electrical Machines I, chapter 3
- EMF and efficiency of short shunt compound generator (50 A, 200 V) · Electrical Machines I, chapter 3 · asked 2×
- Wave-wound shunt generator, power absorbed by load · Electrical Machines, chapter 3
- Compound generator EMF in long and short shunt · Electrical Machines I, chapter 3 · asked 2×
- Long shunt compound generator speed · Electrical Machine, chapter 3
- Armature dimensions of 50 kW shunt generator · Electric Machine Design, chapter 5
- EMF of short shunt compound generator (0.5 Ω armature) · Electrical Machines I, chapter 3 · asked 2×
- 4-pole shunt generator, 3 kW at 120 V · Electrical Machine, chapter 3 · asked 2×