- 2075 Asoj · 6 marks
Rotor slots and turns, 90 kW motor
Short answer
From voltage ratio and mmf balance: 72 rotor slots, 4 conductors per slot give 48 turns per phase, open-circuit line voltage 381 V; full-load rotor current ≈150 A per phase.
A 90 kW, 500 V, three phase, 8 pole slip ring induction motor having 0.9 efficiency and power factor of 0.86 has 63 stator slots with 6 conductors per slot. If the slip ring voltage on open circuit is to be about 400 V, find the number of rotor slots, rotor turns per phase, number of conductors per slot and appropriate full load rotor current per phase. Both stator and rotor are star connected.
Data: 90 kW, 500 V, 8 poles, star/star, , pf , 63 stator slots with 6 conductors per slot, rotor open-circuit (slip-ring) voltage about 400 V.
Stator turns per phase
Rotor turns per phase (approximate)
At standstill the voltage ratio equals the turns ratio (taking ):
Rotor conductors .
Number of rotor slots
- Stator slots per pole per phase (fractional).
- For a wound rotor an integral value is used, and .
- Take : 72 slots.
Conductors per slot and rotor turns
, so take 4 conductors per slot (double layer):
Slip-ring voltage on open circuit:
Full-load rotor current
Stator current:
Rotor mmf is about 85% of stator mmf (the rest is magnetising), so:
Answer: 72 rotor slots, 4 conductors per slot, turns per phase (open-circuit voltage V), full-load rotor current A per phase.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- 200 kW 4-pole slip ring motor (delta) · Electric Machine Design, chapter 4 · asked 4×
- 200 kW 1420 rpm slip ring motor (star) · Electric Machine Design, chapter 4 · asked 5×
- 250 HP 1410 rpm slip ring motor (kw 0.955) · Electric Machine Design, chapter 4 · asked 6×
- 250 HP 1410 rpm slip ring motor (kw 0.95) · Electric Machine Design, chapter 4 · asked 3×
- 250 HP 4-pole slip ring motor · Electric Machine Design, chapter 4 · asked 5×
- Air gap and rotor bars, 10 kW motor · Electric Machine Design, chapter 4
- Delta induction motor: slip, rotor emf, turns ratio · Electrical Machines, chapter 5 · asked 2×
- Starting current and rotor resistance for 150 kW slip ring motor · Electrical Machines I, chapter 5
- 6-pole induction motor: slip, losses, efficiency · Electrical Machines, chapter 5
- Effect of five-times rotor resistance on 40 kW slip ring motor · Electrical Machines I, chapter 5