200 kW 1420 rpm slip ring motor (star)

Short answer

Main dimensions: D=40.5 cm, L=38.2 cm; with star connection, Ts=18. Using 72 slots, 3 conductors per slot and 2 parallel paths per phase. Conductor cross-section is 50.9 mm², slot area about 382 mm².

Determine the main dimensions, turns per phase, number of slots, conductor size and slot area of 200 kW, 3φ, 400 V, 50 Hz, 1420 rpm slip ring induction motor. Assume Bav = 0.5 Wb/m², ac = 30000 ampere conductors per meter, efficiency = 0.9, p.f = 0.9, current density = 3.5 A/mm². The slot space factor is 0.4 and the ratio of core length to pole pitch is 1.2. The machine is star connected.

Data: 200 kW, 400 V, 50 Hz, 1420 rpm, so 4 poles and ns=25n_s = 25 rps; star connected; η=0.9\eta = 0.9, pf =0.9= 0.9; Bav=0.5B_{av} = 0.5, ac=30000ac = 30000; δ=3.5\delta = 3.5 A/mm²; L/τ=1.2L/\tau = 1.2. Assume Kw=0.955K_w = 0.955.

Main dimensions

Q=2000.9×0.9=246.9 kVAC0=11×0.5×30000×0.955×10−3=157.58D2L=246.9157.58×25=0.06268 m3\begin{aligned} Q &= \frac{200}{0.9 \times 0.9} = 246.9\ \text{kVA} \\ C_0 &= 11 \times 0.5 \times 30000 \times 0.955 \times 10^{-3} = 157.58 \\ D^2L &= \frac{246.9}{157.58 \times 25} = 0.06268\ \text{m}^3 \end{aligned}

L=1.2×πD/4=0.9425DL = 1.2 \times \pi D/4 = 0.9425D, so D3=0.0665D^3 = 0.0665:

D=0.405 m,L=0.382 mD = 0.405\ \text{m}, \qquad L = 0.382\ \text{m}

Turns per phase

Φ=BavτL=0.5×0.318×0.382=0.0608 WbEph=400/3=230.9 VTs=230.94.44×50×0.0608×0.955=17.9≈18\begin{aligned} \Phi &= B_{av}\tau L = 0.5 \times 0.318 \times 0.382 = 0.0608\ \text{Wb} \\ E_{ph} &= 400/\sqrt3 = 230.9\ \text{V} \\ T_s &= \frac{230.9}{4.44 \times 50 \times 0.0608 \times 0.955} = 17.9 \approx 18 \end{aligned}

Number of slots

Total conductors =6×18=108= 6 \times 18 = 108 with one path. With 48 slots this gives 2.25 per slot (not a whole number) and 36 slots gives a large slot pitch (35 mm). Use 2 parallel paths per phase and q=6q = 6: Ss=3×4×6=72S_s = 3 \times 4 \times 6 = 72, slot pitch =π×405/72=17.7= \pi \times 405/72 = 17.7 mm. Conductors =2×108=216= 2 \times 108 = 216, i.e. 3 per slot, still giving 18 series turns per phase.

Conductor size

Iph=2469143×400=356.4 AIc=356.42=178.2 A per pathas=178.23.5=50.9 mm2\begin{aligned} I_{ph} &= \frac{246914}{\sqrt3 \times 400} = 356.4\ \text{A} \\ I_c &= \frac{356.4}{2} = 178.2\ \text{A per path} \\ a_s &= \frac{178.2}{3.5} = 50.9\ \text{mm}^2 \end{aligned}

(e.g. a strip about 4×12.74 \times 12.7 mm).

Slot area

Aslot=3×50.90.4=381.8 mm2A_{slot} = \frac{3 \times 50.9}{0.4} = 381.8\ \text{mm}^2

Answer: D=40.5D = 40.5 cm, L=38.2L = 38.2 cm; Ts=18T_s = 18; 72 slots (3 conductors per slot, 2 parallel paths); conductor 50.9 mm²; slot area ≈382\approx 382 mm². (With a single path, 36 slots × 3 conductors would also give Ts=18T_s = 18, but with a large slot pitch.)